  • Page 1 Bio-logic NavPRO ONE ® ® QUICK START GUIDE ASSR...
  • Page 2: Start Menu

    Bio-logic NavPRO ONE ® ® QUICK START GUIDE Turning On/Off, and charging the device On/off button on Power supply right side connector Start menu Note: this screen (test options) can vary depending on your set up Battery status Current time Select patient Customize settings Additional...
  • Page 3 Bio-logic NavPRO ONE ® ® QUICK START GUIDE Testing Auditory Steady State Response (ASSR) Connect the electrode cable to the white and the probe to the red connector. Connect the transducer to the appropriate connector: Headphones or insert earphones: blue connector Probe: red connector Second probe for binaural testing:...
  • Page 4 Bio-logic NavPRO ONE ® ® QUICK START GUIDE If you are using insert earphones, select the proper size ear tips and place it in the ear canal. If you are using headphones, place them over the ears. Select ASSR Select the protocol you would like to use. To change the parameters, select one of the presets and then the tools button at the bottom of the screen: Configurable test parameters Half octave stimuli...
  • Page 5 Bio-logic NavPRO ONE ® ® QUICK START GUIDE Select the test ear by pressing either the Right or Left button, or Right + Left for binaural testing. Binaural testing is available when headphones, insert phones or two ear probes are connected (if stimulating at low intensity levels only). Make sure the patient is sitting or lying down comfortably.
  • Page 6 Bio-logic NavPRO ONE ® ® QUICK START GUIDE If you are using an ear probe, a calibration will be performed together with the impedance check. You can select the simple calibration or the expert calibration mode in the device set up. Note: the probe can only be used for low stimulus intensity testing.
  • Page 7 Bio-logic NavPRO ONE ® ® QUICK START GUIDE ASSR test results Please note that the estimated audiogram is only available in the adaptive test mode. Note: These circles Print results to a label or indicate that other to a pdf file screens are available to view.
  • Page 8: Copyright Notice

    Internet: www.pathme.de Healthcare solutions with one thing in mind. You. ©2020 Natus Medical Incorporated. All Rights Reserved. All product names appearing on this document are trademarks or registered trademarks owned, licensed to, promoted or distributed by Natus Medical Incorporated, its subsidiaries or affiliates. 7-26-1389-EN Rev01 Natus Medical Incorporated natus.com...