QUICK START GUIDE
Quick start

Advertisement

loading

Summary of Contents for natus Bio-logic AuDX PRO

  • Page 1 Bio-logic AuDX ® ® QUICK START GUIDE Quick start...
  • Page 2: Start Menu

    Bio-logic AuDX ® ® QUICK START GUIDE Turning On/Off and changing the device On/off button on right side Power supply connector Start menu Note: this screen (test options) can vary depending on your set up Current time Battery status Select patient Customize settings View test result history for selected patient...
  • Page 3 Bio-logic AuDX ® ® QUICK START GUIDE Testing: Distortion Product Otoacustic Emissions (DPOAE) Screening Connect the probe to the red connector. Select one of the Presets for DPOAE Screening Select the appropriate ear tip size and place it on the probe tip. Insert the probe in the ear making sure that the ear tip fits tightly into the ear canal.
  • Page 4 Bio-logic AuDX ® ® QUICK START GUIDE Progress for each test A calibration will be performed prior to measurement. frequency A green light indicates successful calibration (below left). After successful ear probe calibration, the test will start automatically. Probe fit override for patients with Overall test Noise floor PE tubes or tympanic membrane...
  • Page 5 Bio-logic AuDX ® ® QUICK START GUIDE DPOAE screening test results Overall screening test result Green check marks indicate valid response. Red circles indicate no valid response Red (right ear) or blue (left ear) bars show response amplitude. Grey bars show noise amplitude Retest frequencies that did not pass...
  • Page 6 Bio-logic AuDX ® ® QUICK START GUIDE DPOAE diagnostic / high reolution Connect the probe to the red connector. Select one of the Presets for DPOAE Diagnostic. Select the appropriate ear tip size and place it on the probe tip. Insert the probe in the ear making sure that the ear tip fits tightly into the ear canal.
  • Page 7 Bio-logic AuDX ® ® QUICK START GUIDE A calibration will be performed prior to measurement. A green light indicates successful calibration. After successful ear probe calibration, the test will start automatically. Please note that the presets for DPOAE diagnostics are HiRes, which allows testing frequencies in 10 Hz increments or up to 30 points per octave.
  • Page 8 Bio-logic AuDX ® ® QUICK START GUIDE DPOAE diagnostic test results Outcome for each test sorted by f2 and L2. Red or blue bars indicate Multilevel test results shown. Green check marks response, grey bars indicate Tap on screen to view details indicate valid response noise for each level tested.
  • Page 9: Copyright Notice

    Internet: www.pathme.de Healthcare solutions with one thing in mind. You. ©2020 Natus Medical Incorporated. All Rights Reserved. All product names appearing on this document are trademarks or registered trademarks owned, licensed to, promoted or distributed by Natus Medical Incorporated, its subsidiaries or affiliates. 7-26-1385-EN Rev01 Natus Medical Incorporated natus.com...