16. Troubleshooting

WARNING
Always switch the machine off and remove the mains plug prior to all maintenance and cleaning work.
Fault
Possible cause
Saw blade without pins
Saw blade clamping screw (28/29) not tightened
loosens after switching off
enough
the engine
Motor does not start
Failure mains fuse
Extension cable defect
Fine-wire fuse defective
Connections on the motor or switch defect
Motor or switch defect
Saw blades brake
Tension set incorrectly
Load too high
Incorrect saw blade type
Workpiece not fed straightly
Saw blade oscillates, not
Holders not aligned
aligned straightly.
24
GB/IE
Remedy
Tighten the saw blade clamping screw (28/29)
Check the mains fuse.
Change extension cable.
Check the fine-wire fuse and, if necessary, replace it with
a fine-wire fuse of the same type.
Have it checked by an electrician.
Have it checked by an electrician.
Set correct tension
Feed workpiece more slowly
Use correct saw blades
Avoid lateral pressure
Open the screws that fasten the holders. Bring the hold-
ers into the vertical position and tighten the screws again.