Download Print this page
BEA MAGIC SWITCH MS21H Quick Start Manual

BEA MAGIC SWITCH MS21H Quick Start Manual

Hardwired, stainless steel, touchless, activation sensor

Advertisement

Quick Links

Visit website for
available languages of
this document.
DESCRIPTION
1
PRODUCT FAMILY
6" ROUND STYLES
10MS21HR
text only
TECHNICAL SPECIFICATIONS
Technology
Detection Mode
Supply Voltage
Current Consumption
Temperature Range
Enclosure Rating
Sensing Zone
Relay
Dimensions (0verall)
Wire Harness Length
Material
75.5737.12 MS21H 20201014
2
5
6
3
10MS21HRLL
10MS21HR1
logo only
text & logo
capacitive sensing
proximity
12 – 24 VAC/VDC
37 mA (typical)
-20 – 120 °F
NEMA 4
0 – 4"
1-Form A Solid State Relay
0.4A 60 VAC/VDC (max)
6" Round:
4.75" Square:
6 inches (5-conductor)
stainless steel (faceplate)
clear polycarbonate (mounting ring, backplate, enclosure)
MAGIC SWITCH: MS21H
10MS21HS
text only
Sensing Zone is dependent upon size (area) of object, orientation of object, speed of
7" (diameter) × 0.5" (D)
5.75" (H) × 5.75" (W) × 0.5" (D)
A 5-conductor wire is needed between the sensor and the door control.
Specifications are subject to change without prior notice.
Hardwired, Stainless Steel, Touchless,
Activation Sensor
4
7
8
4.75" SQUARE STYLES
10MS21HSLL
logo only
object, and environmental conditions.
All values measured in specific conditions.
1. faceplate
2. mounting holes
3. set screws
4. backplate
5. NEMA 4 enclosure
6. wire harness
7. DIP-switches
8. potentiometer
10MS21HS1
text & logo
Page 1 of 4

Advertisement

loading

Summary of Contents for BEA MAGIC SWITCH MS21H

  • Page 1 MAGIC SWITCH: MS21H Hardwired, Stainless Steel, Touchless, Visit website for Activation Sensor available languages of this document. DESCRIPTION 1. faceplate 2. mounting holes 3. set screws 4. backplate 5. NEMA 4 enclosure 6. wire harness 7. DIP-switches 8. potentiometer PRODUCT FAMILY 6”...
  • Page 2 WIRING IMPORTANT WIRING NOTES: • Always use a BEA-provided isolation module (polarity-sensitive) for powering each MS21. Red must be connected to power (+) and black connected to power (-). • It is recommended that 300 V, low-voltage cabling, shielded wire be used during installation.
  • Page 3 WIRING (cont.) It will take approximately 10 seconds to complete the initialization sequence once powered. Wire-nut harness wires and isolation module wires together and then connect the isolation module wires to the door control using the chart or visual representation below. NOTE: From isolation module to ACT, use either green (NO) OR yellow (NC).
  • Page 4 BEA, Inc. does not guarantee any use of the sensor outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the type of door/gate system.

This manual is also suitable for:

Magic switch 10ms21hrMagic switch 10ms21hrllMagic switch 10ms21hr1Magic switch 10ms21hsMagic switch 10ms21hsllMagic switch 10ms21hs1