Understanding Error Codes - Navien NCB-190/060H User's Information Manual

Ncb-h condensing combi-boilers
Hide thumbs Also See for NCB-190/060H:
Table of Contents

Advertisement

5.2 Understanding Error Codes

When an error code appears on the front panel, refer to the following chart for a definition and possible remedy
for the situation.
Error Code Reason
E001
Heatexchanger over temperature
E003
Ignition failure
E004
False flame detection
E012
Flame loss
E016
Overheating of heat exchanger
E030
Abnormal exhaust temperature
E031
Overheating of burner
E046
Abnormal operation: limit control
E047
Abnormal operation: exhaust thermostat
E060
Abnormal operation: dual venturi
E109
Abnormal operation: fan motor
E110
Abnormal air pressure
E205
Heating supply thermistor open or short circuit
E218
Heating return thermistor open or short circuit
E278
Abnormal operation: system supply thermistor
E279
Abnormal operation: system return thermistor
E351
Abnormal Auto feeder valve (make-up water)
E352
High water pressure
E353
Abnormal operation: water pressure sensor
E407
Domestic hot: thermistor open or short circuit
E421
Domestic cold: thermistor open or short circuit
E434
Abnormal operation: water adjustment valve
E439
Abnormal operation: flow sensor
E441
Domestic hot 2: thermistor open or short circuit
E445
Abnormal operation: Bypass mixing valve
E515
Abnormal operation: PCB
E517
Abnormal operation: Dip switch setting
E594
Abnormal operation: EEPROM
Self-diagnostic/Action
Manual RESET
Auto RESET
Manual RESET
Manual RESET
Auto RESET
Manual RESET
Manual RESET
Manual RESET
Alarm
Manual RESET
Auto RESET
Manual RESET
Auto RESET
Alarm
Manual RESET
Manual RESET
Auto RESET
Alarm
Alarm
Alarm
Manual RESET
Auto RESET
Auto RESET
Auto RESET
Auto RESET
Alarm
Alarm
Auto RESET
Alarm
Manual RESET
Alarm
Manual RESET
Alarm