4.2 Understanding Error Codes

When an error code appears on the front panel, refer to the following chart for a definition and possible remedy for the situation.
Error Code
Reason
003
Ignition failure
004
False flame detection
012
Flame loss
016
Heat exchanger overheat
030
Abnormal exhaust temperature
046
Abnormal operation: Heat exchanger overheating sensor
047
Abnormal operation: Exhaust thermostat
060
Abnormal operation: Dual venturi limit switch
109
Abnormal operation: Fan
110
Exhaust blockage (Condensate blockage)
127
Abnormal operation: APS
205
Heating supply thermistor open or short circuit
218
Heating return thermistor open or short circuit
302
Low water pressure
352
High water pressure
353
Abnormal operation: Water pressure sensor
407
Abnormal operation: Hot water outlet thermistor
421
Abnormal operation: Cold water inlet thermistor
515
Abnormal operation: Relay feedback (PCB)
517
Abnormal operation: DIP switch setting (PCB)
594
Abnormal operation: EEPROM (PCB)
615
Abnormal operation: Input and memory (MCU)
740
Abnormal operation: Outdoor temperature sensor
782
Abnormal operation: Main panel communication
If the error code is not cleared by resetting the boiler functioning (see "3.5 Resetting the Boiler") or if it occurs repeatedly, call the nearest
official Technical Assistance Service (TAS), indicating the number of the error code appearing on the front panel.
Reset
Manual reset
Auto reset
Manual reset
Manual reset
Manual reset
Auto reset
Manual reset
Auto reset
Auto reset
Manual reset
Manual reset
Manual reset
Auto reset
Alarm
Auto reset
Auto reset
Auto reset
Alarm
Auto reset
Manual reset
Manual reset
Alarm
Manual reset
Auto reset
Auto reset