Resetting The Boiler - Navien NCB-190/060H User's Information Manual

Ncb-h condensing combi-boilers
Hide thumbs Also See for NCB-190/060H:
Table of Contents

Advertisement

Item
22. Flow Control
100 - Close State
Valve Status
23. Mixing Valve
0 - Close State
Status
24. Exhaust Temp
Exhaust Temperature (°F)
Outdoor Reset Status
25. Outdoor Reset
(Enable/Disable)
Outdoor Reset Curve Load
Type (Displayed when the
outdoor reset option "20.
Outdoor Reset"is enabled.)
1: Finned Tube Baseboard
26. Outdoor Reset
2: FAN Coil
Curve
3: Cast Iron Baseboard
4: Low Mass Radiant
5: High Mass Radiant
6: Radiator
7: Custom (Set by installer.)
27. Boost Interval
Boost Interval Set Time
Time
(min)
Sea Level (0 - 2,000 ft)
Level 1 (2,000 - 5,400 ft)
28. High Altitude
Level 2 (5,400 - 7,700 ft)
Level 3 (7,700 - 10,100 ft)
Well Pump Status
29. Well Pump
OFF - Unused, ON - Used
30. Model
Model Type
31. Gas
Fuel Type (NG/LPG)
32. Main F/W Ver
Main Firmware Version
Controller Panel Firmware
33. Panel F/W Ver
Version
Description

3.4 Resetting the Boiler

If an error message appears during boiler operation,
clear the message and resolve the problem. Press
the Back button (
) on the front panel to reset the
boiler.
If resetting the boiler does not solve the problem,
refer to the Troubleshooting section of this manual
or contact Technical Support at 1-800-519-8794.
Operating the Boiler
13