Samsung SCL810 Service Manual page 33

8mm camcorder
Table of Contents

Advertisement

Alignment and Adjustment
2. Zoom VR Center
1) Camera "E-E", 3100°K gray-scale chart.
2) Video(output) jack and EVR.
3) Connect monitor TV to video(output) jack.
4) Press the "BLC (MODE UP)/FADE(MODE
DOWN)" button so that the OSD state is "OD6.
XX XX".
5) Press "ENTER(CONFIRM)" button.
6) Then, the microprocessor will work ;
- Find the Zoom VR Center position
- Store the data to mode 0B7.
3. Auto hall
1) Camera "E-E", 3100°K gray-scale chart.
2) Video(output) jack and EVR.
3) Connect monitor TV to video(output) jack.
4) Press the "BLC(MODE UP)/FADE(MODE
DOWN)" button so that the OSD state is "OCD.
XX XX".
5) Press "ENTER(CONFIRM)" button.
6) Then, the microprocessor will work ;
- IRIS open, HALL maximum value found,
- IRIS closed, HALL minimum value found,
- IRIS open, HALL maximum value found,
- Store the data to mode 00A and mode 00B.
- Store the HALL min./max. data to mode 0C1
and mode 0C2.
1-32
4. AUTO IRIS
1) Camera "E-E", 3100°K gray-scale chart.
2) Video(output) jack and AF MICOM.
3) Connect video(output) jack to waveform moni-
tor input jack and monitor TV jack respectively.
4) Press the "BLC(MODE UP)/FADE(MODE
DOWN)" button so that the OSD state is "OCE.
XX XX".
5) Press "ENTER(CONFIRM)" Button.
6) Then, the micro process will work;
- IRIS open, IRIS control minimum Value found.
- IRIS close, IRIS control minimum Value found.
- Store the data to mode 0B5, 0B6, 0C7 and 0C8.
7) The OSD shows "O.K".
Center of
white level
100 IRE
Optical
black level
40US
5. Auto white balance
1) Camera "E-E", 3100°K/5100°K gray-scale chart.
2) Video(output) jack and AF MICOM.
4) Connect vectorscope input jack to video(out-
put) jack.
3) Press the "BLC(MODE UP)/FADE(MODE
DOWN)" button so that the OSD state is "OCF.
XX XX".
a. W/B Indoor
a-1. Aim the camera at a 3100°K gray-scale chart
illuminated at 1500 to 2000 lx. (40us)
a-2. Press "ENTER(CONFIRM)" button so that the
white vector moves to the center on screen of
the vectorscope.
a-3. Store the data to mode 0A6, 0A7, 0A8, 0A9
a-4. The OSD shows "OK!".
b. W/B Outdoor
b-1. Aim the camera at a 5100°K gray-scale
(3100°K+CCB12) chart illuminated at 1500 to
2000 lx. (40us)
H
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scl860Scl870

Table of Contents