16. Route long orange wire from relay assembly (up to
door panel switch) and connect to "NO". Route
orange wire from door panel switch (down to
control panel) through the blower partition and
control panel bushing as shown in Figure 1 on
page 4.
NOTE: Not all models will have bushing in blower
partition. A 7/8" hole can be drilled and
supplied bushing can be installed.

DOOR SWITCH ASSEMBLY

USE BRACKET 113-908
1- 3/4"
INSTALL SWITCH ASSEMBLY
TO DEFLECTOR USING
SELF DRILLING SCREWS
PROVIDED
17. Locate low voltage strip in control panel. Seat
spade end of orange wire from panel switch
assembly under the "G" terminal on the low
voltage strip assembly, then seat spade end of
black/white wire from coil on relay assembly under
the "C" terminal on low voltage strip (see Figure 5
on page 8).
FIGURE 4
Install Panel Switch Assembly
DOOR SWITCH ASSEMBLY
LOCATION WHEN NO DEFLECTOR
IS USED.
SHOWN WITH
DEFLECTOR INSTALLED
ROUTE WIRES BEHIND
DEFLECTOR AND THROUGH
BUSHINGS TO CONTROL PANEL
MIS-4330