Page 1
CO OLORa do™6 USER R MANU Chauvet, 3000 N 29 Ct, Hollywood, FL L 33020 U.S.A. (800) 762 -1084 – (954) 929-1 X (954) 929-5560 www. chauvetlighting.com Snapsh OK on Dim mmer Outdoor O Sound Activ vated DMX51 Master/Sl lave...
ABLE OF ONTENTS 1. BEFORE YOU BEGIN ... 3 ... 3 HAT IS INCLUDED ... 3 NPACKING NSTRUCTIONS ... 4 AFETY NSTRUCTIONS LED E ... 4 XPECTED IFESPAN 2. INTRODUCTION ... 5 ... 5 EATURES DMX C ... 6 HANNEL UMMARY Product Overview ...
There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-929-1115. Caution! After prolonged periods of operation, the fixture chassis may reach high temperatures.
2. I NTRODUCTION Features • 3~12-channel DMX-512 LED bank system (with ID addressing) • Separate DMX channels for red, green, blue, cyan, magenta, yellow, and white • Blackout/static/dimmer/strobe • Separate RGB control over each individual module • RGB color mixing with or without DMX controller •...
DMX Channel Summary The COLORado™6 has a total of 4 DMX channel configurations, referred to as “Personalities” in this manual and in the fixture onboard control board. The 4 personalities are [STAGE 1, STAGE2, ARC1, ARC 1+D] [STAGE 1] DMX M HANNEL [STAGE 1] DMX M HANNEL...
Page 7
[STAGE 2] DMX M HANNEL HANNEL 1+D] HANNEL COLORado™6 User Manual ESCRIPTION Module #1 Module #2 Module #3 No Function Strobe Mode Selection 0 <> 244 : DMX Mode 1 0245<> 255 : DMX Mode 2 ID Addressing No Function ESCRIPTION Green Blue...
Product Overview Interlocking Connectors Power Link Out DMX Out DMX In Each LED cluster is referred to as a module COLORado™6 User Manual Hanging Yoke Safety Cable Power In Power Out 180° Tilt Adjustment Control Panel 1/15/2008 11:12 AM...
IP66 outdoor rating. However, this will not void the standard 2-year warranty that all Chauvet DMX fixtures carry, provided the operating voltages are within the proper range.
It is recommended to use at least 2 mounting points per fixture. You can order “C” and “O”- clamps from any CHAUVET dealer or distributor: CLP-15, CLP-06, CLP-16 Block access below the work area and use suitable and stable platform when installing or servicing fixture.
Stacking The COLORado™6 can be stacked vertically and horizontally to create a blinder or strip light. Stack them horizontally to increase intensity of the projection for more distant throws or to use as a blinder effect. The strip light stacking can be used for runway lighting or cycloramas.
s Assem mbly Insta allation/Re e COLORado™6 c comes with 15° lens tional lens assembl lies available as ac inst tructions for proper r replacement/insta 6 screws around d each LED modu There are 6 sc crews located ar After removing g the front cover LED’s.
Maximum recommended number of fixtures on a serial data link: 32 fixtures Data Cabling To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. Note! CHAUVET Model No: DMX5M, or DMX5F. The chart below details a proper cable conversion: IN TO...
4. O PERATING Control Options The COLORado™ 6 is addressable in the DMX range of 001 to 512 in its simplest control form, this allows for the control of 20 fixtures; however, a secondary “ID” address system exists for use in a limited DMX universe and architectural environments.
DMX-512 addressing with ID address 1. Follow instructions 1 ~ 4 for DMX512 addressing. 2. Activate ID addressing in each fixture by setting panel function {ID ON/OFF} to ON. {MENU} {Settings) 3. For every DMX512 starting address the user can set 66 separate ID addresses. 4.
COLORcon™ setup FIXTURE CONTROL PANEL SETUP Activate ID addressing in each fixture by setting panel function {ID ON/OFF} to ON. {MENU} Set ID addresses in each fixture by setting panel function {ID address} to incremental values. (I.e. 1,2,3,4,5,6,etc…) {MENU} It is not necessary to set the DMX address. CONTROLLER SETUP When using the {Effect program} function, it is necessary to set the {Settings} {Range} setting, which is the quantity of fixtures in series.
Setting the DMX address Each fixture requires a "start address" from 1 to 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, 105 and 106.
Menu Map UNCTION Static color DMX512 Personality Run Mode Auto program Settings Password Manual Power ON/OFF The COLORado™6 can be turned on and off using the control panel. OWER CTION When {MENU} is displayed in the LCD panel, hold down the (EXIT) button for 3 Turn OFF seconds to turn off the fixture.
STAGE 1 [DMX CONTROL MODE 2] HANNEL ALUE UNCTION Module 1 No Function Green Blue Yellow Cyan Magenta Pink-White Module 2 No Function Green Blue Yellow Cyan Magenta Pink-White Module 3 No Function Green Blue Yellow Cyan Magenta Pink-White No Function Strobe No Function Mode Selection...
STAGE 2 [DMX CONTROL MODE 1] HANNEL ALUE Dimmer No Function No Function Green No Function Blue No Function Color Macros No Function Red (100%) Red (85%) + Green (15%) Red (60%) + Green (40%) Yellow (100%) Red (15%) + Green (85%) Red (40%) + Green (60%) Green (100%) Green (85%) + Blue (15%)
STAGE 2 [DMX CONTROL MODE 2] HANNEL ALUE ID Address Selection COLORado™6 User Manual UNCTION Module 1 No Function Green Blue Yellow Cyan Magenta Pink-White Module 2 No Function Green Blue Yellow Cyan Magenta Pink-White Module 3 No Function Green Blue Yellow Cyan...
ARC 1 HANNEL ALUE UNCTION No Function Green No Function Blue No Function ARC 1+D HANNEL ALUE UNCTION Dimmer No Function No Function Green No Function Blue No Function COLORado™6 User Manual 100% 100% 100% 100% 100% 100% 100% 1/15/2008 11:12 AM...
Important Notes about STAGE 1+STAGE 2 [DMX Mode 1] RED, GREEN AND BLUE SELECTION • Channels 1, 2 and 3 control overall intensity of each respective color. • Channels 1, 2 and 3 can be combined to create an unlimited range of colors. •...
Important Notes about STAGE 1+ STAGE 2 [DMX Mode 2] MODULE SELEC T ION • Simplified control of modules using channels 1,2 & 3. STROBE • Controls the strobe of channels 1, 2 and 3 simultaneously. • Speed of the strobe is adjustable from 0 to 20 Hz. MODE SELECTION •...
5. COLOR ™ C Overview LCD Display MODE SETUP MODE Accesses main menu or backs out of sub- menu SETUP Selects the currently displayed menu or confirms the current function value Setup Connect from the OUT on the controller to the DMX Input side of the COLORado™ using a DMX XLR cable.
Custom Program Select from the eight existing [Custom] programs and it will instantly play. Enter the [Edit] section to create or edit program. You can create or edit up to 100 scenes. To program less than 100 scenes, set the [Step time] of the scene after your last scene to 0.
[Reset to factory settings] This function will reset all the settings to the factory defaults except for [Custom] programs. Setting [Schedule] [Wash program] [Effect program] [DMX address] [Range] [Allow edit] [Password ON/OFF] [Set password] Activating password mode Set [Password] function to [ON]. This will prompt the user for a password every time the controller is powered on.
LED which has failed will no longer function. -Note: In the event of LED failure, a replacement LED PCB assembly may be purchased directly from Chauvet Check that the lens assembly is installed properly. If the lens assembly is...
Blow-out Diagram: Parts/Assembly ITEM# PART DESCRIPTION Front Cover Rubber Seal Clear Plastic Lens cover LED LENS Complete Set Led PCB Array Rigging Knob Master PCB Electronic Transformer Plastic Seal for Wires Knob for Bracket Adjustment COLORado™6 User Manual 1/15/2008 11:12 AM...
Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’) COLORado™6 User Manual...
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RMA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
Master PCB Connection Diagram LED PCB Alignment/Layout Diagram Each color Led is broken down into individual circuits (red-circuit#1, blue- circuit#2, green-circuit#3). If a single LED fails “open”, then the entire circuit will stop functioning, because they are wired in “series”. If a single LED fails in a “short”, then only that single LED will stop functioning, while the rest of the circuit will...