LG LSCE365ST Service Manual page 68

Ceramic glass radiant cooktop
Hide thumbs Also See for LSCE365ST:
Table of Contents

Advertisement

Components
Bridge surface units:
Left Front(LF),
Left Center(LM)
and
Left Rear(LR)
Element
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
COMPONENT TEST
Test procedures
5. Touch the ohmmeter test leads to limiter terminals
1A and 2A. The meter should indicate
continuity(0Ω)
6. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below (150˚F/65.5˚C), the
meter should indicate an open circuit(infinite).
With the temperature above (150˚F/65.5˚C), the
meter should indicate continuity (0Ω).
- 68 -
Results
Normal: continuity
(below 0.5 Ω)
If not replace
Normal: continuity
(below 0.5 Ω)
If not replace
<Normal>
Below (150˚F/65.5˚C)
open circuit (infinite).
Above (150˚F/65.5˚C)
continuity (0 Ω)
If not replace
<Normal>
Below (150˚F/65.5˚C)
open circuit (infinite).
Above (150˚F/65.5˚C)
continuity (0 Ω)
If not replace
LGE Internal Use Only