INSTALLATION INSTRUCTIONS
ELECTRICAL CONNECTIONS
IF COOKTOP IS USED IN A NEW BRANCH CIRCUIT INSTALLATION (1996 NEC), MOBILE
HOME, RECREATIONAL VEHICLE, OR WHERE LOCAL CODES DO NOT PERMIT
GROUNDING TO THE NEUTRAL (WHITE) WIRE
Observe all governing codes and local
ordinances.
Disconnect the power supply.
At the circuit breaker box, fuse box or junction
box, connect appliance and power supply cable
wires as shown.
WARNING: If connecting to a 4-wire power
supply cable electrical system, the
appliance frame connected ground
wire MUST NOT be connected to
the neutral wire of the 4-wire
electrical system.
COOKTOP INSTALLATION
Visually inspect the cooktop for damage.
Make sure all cooktop screws are tight
(see below for locations).
Carefully lower the cooktop into the counter-top
cutout, making sure not to trap any wires.
NOTE: Do not use caulking compound. The
cooktop must be removable, should service be
required.
LGE Internal Use Only
(cont.)
4-WIRE GROUNDED JUNCTION BOX
Green wire(ground)
- 17 -
Cable from power supply
Ground
wire
Red
wires
Cable from cooktop
Screws
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
White wire
(no connection)
Black
wires
Junction box
UL-listed conduit
connector