Replacing and Cleaning the UV-C Bulb & Filter
6. Lift bulb holder from cylinder. Do not touch bulb. If cleaning, insert
soft, dry cloth into cylinder and remove. Repeat if necessary. Do not
touch bulb with bare hands. Fingerprints may result in reduced
performance unless they are removed with an alcohol pad. Use a
soft cloth as a barrier against contact.
7. If NOT replacing the bulb for the first time go to step 8.
If replacing the bulb for the first time, flip bulbholder over so light bulb
faces up. There will be a spring located between the bulb cylinders.
Pull the spring away from the base of the bulb and pull out through
the bulb. Discard spring. Spring is used for shipping purposes only
and does not need to be replaced.
8. Grasp the metal collar on the bulb and pull firmly until bulb unplugs
from the bulb holder. When inserting new bulb, make sure the bulb
snaps and is locked firmly in place. Reassemble by reversing steps 1-8.

REPLACEMENT PARTS

Check out our
Filter Replacement Program
www.guardiantechnologies.com
IMPORTANT: To maintain warranty and the performance
of the product, use Guardian Technologies GENUINE
Replacement Parts only. To Purchase Contact Customer Service
F-6
Filter & Bulb:
Model No. EV9LBL

TROUBLESHOOTING GUIDE

PROBLEM
Unit doesn't operate.
Light flickers.
Fan runs but no light.
Low air flow.
WARNING:
ULTRAVIOLET-C LIGHT IS EMITTED FROM THE BULB WHEN THE UNIT IS ELECTRIFIED,
SEVERE EYE INJURY OR IRRITATION COULD RESULT, UNPLUG THE UNIT WHEN SERVICING
THE BULB TO AVOID EXPOSURE OF EYES AND SKIN TO THE ULTRAVIOLET-C LIGHT.
• Discard the old bulb by following the recommended disposal procedure for a used fluorescent bulb.
• The bulb should only be used in the GermGuardian unit and all instructions for use must
be followed.
WARNING:
MISAPPLYING OR MISUSING THE UV-C BULB COULD CAUSE INJURY TO THE EYES OR SKIN.
NEVER USE THE BULB WITHOUT INSTALLING IT IN THE UNIT AS INSTRUCTED. NEVER OPERATE
THE UNIT WITHOUT THE CAP IN PLACE.
This product can be serviced or maintained only by changing the UV-C bulb. The bulb contains
no serviceable parts. All parts, except the UV-C bulb, are warranted for one year from date
of purchase. See the Limited Warranty. Use of any bulb other than the appropriate GermGuardian
bulb will void the warranty.
You may purchase bulbs directly from Guardian Technologies LLC, or we can provide the names
of retailers who stock our products.
The health aspects associated with this product and its ability to aid in the disinfection of
environmental air have not been investigated by UL.
The purchase of a GermGuardian unit does not prevent illness. The GermGuardian unit is
designed to kill over 99% of bacteria.
GermGuardian is a registered trademark of Guardian Technologies LLC.
SOLUTION
Check that the unit is plugged in.
Call Customer Service at 1.866.603.5900.
Bulb burnt out. See replacing
UV-C Bulb section of manual.
Bulb burnt out. See replacing
UV-C Bulb section of manual.
Check fan setting. Press the power button until
the ring is blue. Replace filter. See Replacing
UV-C Bulb and Filter section of manual.