Note:Please refer to Appendix 1 for the relation between temperature and resistance of temperature sensor.
3.4.11 ―F3‖ Outdoor Ambient Temperature Sensor Error
Error display: ODU mainboard, IDU wired control and IDU receiver light board will
Error judgment condition and method:
Sample the AD value of temperature sensor through temperature sensor detecting circuit and judge the range of
AD value, If the sampling AD value exceeds upper limit and lower limit in 5 seconds continuously, report the error.
Possible reason:
■Poor contact between ambient temperature sensor and terminal in mainboard interface
■Ambient temperature sensor is abnormal
■Detecting circuit is abnormal
Malfunction of
condenser
temperature
sensor
Check if the condenser
temperature sensor on
mainboard is inserted on the
needle stand correctly
Yes
Disconnect
the temperature sensor and
measure if its resistance is
normal
Yes
Replace the
outdoor
mainboard
U-Match 5 SERIES UNIT SERVICE MANUAL
Correctly insert the
No
temperature sensor
on the needle stand
No
temperature sensor
display:F3
51
Replace the