Viessmann Vitoflex 300-RF Technical Data Manual page 6

Wood-fired boiler
Hide thumbs Also See for Vitoflex 300-RF:
Table of Contents

Advertisement

General Information
Delivery Condition
Special delivery condition (partially disbanded)
For special circumstances like restricted space to bring
the boiler into the heating room, the size of the boiler
can be reduced by detaching additional components
to the ones as described in section "Standard delivery
condition". The assembly of these components require
additional assembly time of approximately 6 hours.
Measurements of the largest part for reduced boiler size
Boiler model
RF 150
Minimum size
35b in. x 49a in.
door
(900 mm x
1250 mm)
Minimum
39a in. x 102a in.
ceiling opening
(1000 mm x
(W x H)
2600 mm)
Special delivery condition (fully disbanded)
For special circumstances like heavily restricted space
to bring the boiler into the heating room, the size of the
boiler can be reduced by detaching additional components
to the ones as described in section "Standard delivery
condition" and "Special delivery condition partially
disbanded". The assembly of these components require
welding and additional assembly time of approximately
20 hours.
Measurements of the largest part for reduced boiler size
Boiler model
RF 150
Minimum size
35b in. x 49a in.
door
(900 mm x
1250 mm)
Minimum
39a in. x 85 in.
ceiling opening
(1000 mm x
(W x H)
2160 mm)
6
(continued)
RF 220
46 in. x 61 in.
(1170 mm x
1550 mm)
49a in. x 103a in.
(1250 mm x
2620 mm)
RF 220
46 in. x 59 in.
(1170 mm x
1500 mm)
49a in. x 85c in.
(1250 mm x
2180 mm)
The following additional objects will be delivered
disbanded:
- The heat exchanger and the combustion chamber
are separate
- No brickwork inside the heat exchanger and
combustion chamber
- No insulation and panels are attached to the
heat exchanger
RF 300
RF 400
46 in. x 61 in.
55 in. x 67 in.
(1170 mm x
(1400 mm x
1550 mm)
1700 mm)
59 in. x 122 in.
49a in. x 118 in.
(1500 mm x
(1250 mm x
3100 mm)
3000 mm)
The following additional objects will be delivered
disbanded:
- The heat exchanger is a separate piece
- The flue gas collector is detached from the heat
exchanger
- The boiler door is detached from the heat exchanger
(welding required)
RF 300
RF 400
46 in. x 59 in.
55 in. x 67 in.
(1170 mm x
(1400 mm x
1500 mm)
1700 mm)
49a in. x 98c in.
59 in. x 96b in.
(1250 mm x
(1500 mm x
2510 mm)
2450 mm)
Vitoflex 300-RF Technical Data
RF 540
55 in. x 67 in.
(1400 mm x
1700 mm)
59 in. x 130 in.
(1500 mm x
3300 mm)
RF 540
55 in. x 67 in.
(1400 mm x
1700 mm)
59 in. x 110 in.
(1500 mm x
2800 mm)

Advertisement