Nortel QPC472 Installation Manual page 30

Table of Contents

Advertisement

11 If the added QUD15 is located below the right Network shelf, use the
C21 connector from the QCAD111 power harness instead of the C11.
Otherwise, the procedure is identical.
12 At the QCAD111 power wiring harness, untie and then connect the C17
connectorized power connection cable to the right rear Network shelf
(connect the C19 connectorized cable to the left rear Network shelf).
Do not place the cards in the shelf until Step 12 is completed.
13 Install DTI trunks and enter related shelf and DTI office data into system
memory.
DTI installation
CAUTION
DTI/CPI Installation and data administration
Page 23 of 66