  • Page 1 VIESMANN Installation instructions for contractors Vitoplanar EI2 Type EI2.A450MH, EI2.A700MH Infrared heater VITOPLANAR EI2 6169865 GB 1/2021...
  • Page 2 Safety instructions Please follow these safety instruc- tions closely to prevent accidents and material losses. Safety instructions explained Danger Note This symbol warns against the risk Details identified by the word "Note" of injury. contain additional information. Please note This symbol warns against the risk of material losses and environmen- tal pollution.
  • Page 3: Safety Instructions

    Safety instructions (cont.) Working on the appliance Work on electrical equipment may only Danger ■ be carried out by a qualified electrician. Hot surfaces on the appliance can Only connect appliances to correctly cause burns. ■ installed sockets. Before maintenance and service When working on the appliance, dis- work, switch off the appliance and ■...
  • Page 4 (cont.) Please note Mechanical loads can damage the appliance. Do not lean against the appliance. ■ Do not lean objects against the ■ appliance. Auxiliary components and individual parts For replacement, use only spare parts supplied or approved by Viessmann.
  • Page 5: Disposal Of Packaging

    ■ Horizontal and vertical installation tion Only suitable for wall mounting ■ Large infrared radiant surface ■ Vitoplanar EI2 Note Type Output in kW A Vitoplanar wireless or switch mounting thermostat is EI2.A450MH 0.45 required for operation of the appliance.
  • Page 6: Before Installation

    Before installation Danger Please note The appliance may fall off the wall if unsuitable Stresses caused by installation on uneven surfa- fixing materials are used. This may result in dan- ces can damage the heating surface. gerous injuries and damage to the appliance. Only fit the appliance to level walls.
  • Page 7 Clearance dimensions (cont.) Installation room requirements Please note Impermissible ambient conditions can lead to damage to the appliance (risk of overheating) and to a fire hazard. Do not use the appliance in the immediate ■ vicinity of a bathtub, shower or swimming pool. ■...
  • Page 8: Mounting The Appliance On The Wall

    Mounting the appliance on the wall Fig. 3 Wall mounting bracket 1. Mark out 6 drill holes using a spirit level and the 3. Secure the wall mounting bracket in place using wall mounting bracket. suitable rawl plugs and screws. Note If required, route the connecting cable up or down from behind the wall mounting bracket.
  • Page 9: Electrical Connection

    Mounting the appliance on the wall (cont.) 5. Engage the infrared heater in the wall mounting bracket first on one side, then the other. Then lightly press against it and push it downwards and to the right. Please note Mechanical stress on the surface, e.g. due to people or objects leaning against it, can cause damage.
  • Page 10 Electrical connection (cont.) Connection with plug Danger Note A damaged connecting cable can lead to electric The socket must match the appliance plug. shock and short circuit. Check the connecting cable for damage before installation. Note The appliance must be permanently connected to an earth conductor.
  • Page 11: Specification

    All components must be disposed of correctly. Declaration of Conformity We, Viessmann Werke GmbH & Co. KG, D-35107 Using the serial number, the full Declaration of Con- Allendorf, declare as sole responsible body that the formity can be found on the following website: named product complies with the European directives www.viessmann.co.uk/eu-conformity...
  • Page 12 Viessmann Climate Solutions SE Viessmann Limited 35108 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB Fax: +49 6452 70-2780 Telephone: +44 1952 675000 www.viessmann.com Fax: +44 1952 675040 E-mail: info-uk@viessmann.com Viessmann Climate Solutions SE Viessmann Limited...