To clean a bulkhead connector, remove the device's cap. To
2
clean the connector on a fiber cable, remove only the tip of
the cap.
If necessary for a bulkhead connector, extend the tip of the
3
device.
Push the device straight into the connector until you hear a
4
loud click. See Figure 6. Then remove the device.
Use a video microscope to inspect the connector. If
5
necessary, clean and inspect the connector again.
If the mechanical device does not clean the connector
sufficiently, use a swab and solvent to clean the connector.
Figure 6. How to Use a Mechanical Device

How to Use Swabs, Wipers, and Solvent

To clean bulkhead connectors:
Use a video microscope to inspect the connector. If it is dirty,
1
continue to step 2.
Touch the tip of an optical-grade solvent pen or swab
2
soaked in solvent to a dry, optical-grade wiper.
Touch a new, dry swab to the solvent on the wiper.
3
CLICK!
to Clean Connectors
How to Clean Connectors
CLICK!
ghm09.eps