Replacing the LCD

14
Downloaded from
Elcodis.com
electronic components distributor
Fuse
The LCD assembly consists of four pieces as shown in Figure 5:
Translucent light-dispersing back panel
Flexible elastomeric conducting strip
Plastic bezel for housing the assembly's components
Glass LCD display
With the LCD assembly removed from the PCA, use the following procedure to replace
the LCD:
1. Lift the translucent light dispersing back panel off of the plastic bezel.
2. Remove the pink and black elastomeric strip from its slot in the bezel.
3. Remove the old glass LCD display from the bezel.
Make sure the new LCD display is clean (free of lint and finger prints)
before placing it in position in the bezel.
4. Position the new glass LCD display in the bezel; the silver face should face the rear,
and the stepped portion of the glass should be directly under the elastomeric slot on
the bezel.
5. Drop the elastomeric strip into its slot on the bezel.
6. Position the translucent light-dispersing back panel over the silver side of the glass
LCD display. Make sure the guide pins on the light dispersing back panel are facing
up and that they are on the side opposite the elastomeric strip.
PCA Screws
Figure 5. Accessing the LCD
Note
PCA
Light-dispersing
Back Panel
Glass LCD
Display
Elastomeric
Strip
Gray Plastic
Bezel