Siemens PROFINET SIRIUS 3RW5 Equipment Manual page 134

Soft starters and solid-state switching devices
Hide thumbs Also See for PROFINET SIRIUS 3RW5:
Table of Contents

Advertisement

Functions
8.4 OPC UA server
Byte
Bit
Errors
5
0
Temperature sensor short-circuit
1
Temperature sensor wire break
2
Thermal motor model overload
3
Motor connection wrong
Warnings
Byte
Bit
Warnings
0
0
2-phase control with defective thyristor active
1
Asymmetry limit warning exceeded
2
Check fan
3
Connection abort in manual mode
4
Switching element too hot for Start
5
Current limit - maintenance demanded exceeded
6
Current limit - maintenance demanded undershot
7
Generator operation
1
0
Ground fault limit warning exceeded
1
Main power rotation faulty
2
Switching frequency time not kept
3
Motor heating warning limit exceeded
4
New Ex parameter values detected
5
Active power limit - maintenance demanded exceeded
6
Active power limit - maintenance demanded undershot
7
Preset unequal actual configuration
2
0
Remaining time for tripping warning limit undershot
1
Starting time limit - maintenance demanded exceeded
2
Starting time limit - maintenance demanded undershot
3
Temperature sensor overload
4
Temperature sensor short-circuit
5
Temperature sensor wire break
Variables for NamespaceIndex = 2
Displayed name and level
1s
2n
3rd level
t
d
SIRIUS_Simple
Measured Values
134
Tag
Browse name
SIRIUS_Simple
MeasuredValues
NodeId.
Identifier
i =
1
4
SIRIUS 3RW5 PROFINET communication modules
Equipment Manual, 05/2021, A5E35631297002A/RS-AD/004
Data format
Bool
Bool
Bool
Bool
Data format
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Data format Unit
-
-
-
-