Appendix C

Hardware Specifications

This appendix lists the electrical, environmental, and physical
characteristics of the AT-GPIB board and the conditions under which it
should be operated.
Characteristic
Maximum GPIB Transfer Rate
Power Requirement
(from PC AT I/O channel)
* Actual speed may vary considerably from speed shown because of
system and instrumentation capabilities.
Characteristic
Operating Environment
Component Temperature
Relative Humidity
Storage Environment
Temperature
Relative Humidity
EMI
Characteristic
Dimensions
I/O Connector
© National Instruments Corp.

Table C-1. Electrical Characteristics

Table C-2. Environmental Characteristics

Table C-3. Physical Characteristics

Specification
1.4 Mbytes/s*
+5 VDC 0.66 A Typical
1.5 A Maximum
Specification
0° to 40° C
10% to 90%, noncondensing
-20° to 70° C
5% to 90%, noncondensing
FCC Class B Certified
Specification
10.67 cm by 16.51 cm
(4.2 in. by 6.5 in. )
IEEE 488 Standard 24-pin
C-1
AT-GPIB for SCO UNIX