TROUBLESHOOTING
3) When the DEF-Sensor is defective
DATA1. Temp Table
** Sensor Resistance Reading Location **
F-DEF : Between CN30 #4 and CN76 #1
** 0Ω : Short / ∞Ω : Open
Refer to Circuit Diagram
Sensor MICOM/Connector #
Between Connector CN30"-
F
"4"(RED) and CN76-"1"
DEF
Voltage : Between 4.6V ~ 0.6V
Voltage at IC10 MICOM #
24 is the same as the value
between CN30-"4"(RED)
and CN76-"1"(GRY).
Hotpoint,Mba
4033 Cv
ERROR CODE
(GRY)
PCB and Temp Sensor are normal.
RELATED TITLES
LG_MULTI_F_3828A20097W_1[1]
Start
MAIN PCB Connector
No
CN30 is inserted
properly?
Yes
F-DEF Sensor is
No
normal?
Yes
Voltage between MAIN
NO(Value < 0.6V or Value > 4.6V)
PCB Connector CN30-"4"(RED)
and CN76-"1"(GRY)
Yes
No
Input Voltage at IC10
MICOM Pin #24 is normal?
Yes
Check the connector contact.
Samsung
34648123
Refrigerador
WD856UH
Connector contact defect / 
Reconnect
Replace Temp Sensor
Check the wire connection
Check Soldering Defect & Short