Maintenance Of The Under-Bench Air Conditioner - Dometic FreshWell2000 Operating Manual

Under-bench air conditioner
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Maintenance of the under-bench air conditioner

10
Maintenance of the under-bench air
conditioner
!
WARNING!
Any other maintenance work to that which is described here may
only be carried out by qualified personnel who are familiar with the
risks involved when handling refrigerant and air conditioning
systems as well as the relevant regulations.
Interval
Inspection/maintenance
Regularly
Check the condensation water drainage:
➤ Check whether the condensation water drainage channels
Clean the filter of the air discharge unit (fig. 6, page 5):
Regularly
➤ Pull the filter (1) out of the fastening.
➤ Clean the filter (1) with a detergent solution and let it dry.
➤ Put the dry filter (1) back in.
Once per year
Have the heat exchanger serviced:
➤ Have the heat exchanger of the under-bench air conditioner
Replace the carbon filter (fig. 6, page 5) (optional):
Once per year
➤ Pull the filter (1) out of the fastening.
➤ Remove the carbon filter.
➤ Put a new carbon filter in.
➤ Clean the filter (1) with a detergent solution and let it dry.
➤ Put the dry filter (1) back in.
26
(fig. 5 2, page 5) at the sides of the under-bench air condi-
tioner are clear and the condensation water is able to escape.
serviced by specialist workshop.
FreshWell2000
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

9105306418

Table of Contents