FreshWell2000
6.2

Receiver

The receiver (fig. 2, page 3) contains the following control and display
elements:
No.
Explanation
1
Digital display
2
Red/green LED Constantly lit, red: the stand-by mode is active.
3
Blue LED
4
Orange LED
5
Yellow LED
In case of an alarm the display shows an error code to identify the fault:
Code
Explanation
E1
Room temperature probe fault
E2
Indoor battery temperature probe fault
E4
Control card communication fault (control card failure)
EN
Displays the room temperature.
Constantly lit, green: any other mode is active.
Flashing, red/green: the under-bench air conditioner is
on, but the supply voltage is not present.
Constantly lit: the cooling mode is active.
Flashing: the dehumidification mode is active.
Off: any other mode is active.
Constantly lit: the heat pump mode is active.
Flashing: the heat pump mode is active, but the air
conditioner is not yet producing hot air, because the
defrost function or the preventing cold air function is
active.
The defrost function prevents ice on the external battery
exchanger while in heat pump mode.
The preventing cold air function prevents that cold air is
blown into the vehicle while in heat pump mode.
Off: any other mode is active.
Constantly lit: the timer mode is active.
Off: the timer mode is not active.