CAUTION: Make sure that the motor housing is taped to
the mold, if not positioned correctly the cover will not fit
properly.
3-12 CAP DUCT MOTOR REPLACEMENT
1) Separate the Housing of the Cap Duct Motor.
2) Unscrew 3 screws to disassemble the motor.
3) When replacing the motor, check the position of the door
duct and the link for proper fit.
Duct Door
Link
Cap Duct Motor
Figure 36
Figure 39
Figure 40
NG Position
Figure 41
4) Insert 2 screws.
5) Push housing aside.
- 12 -
Figure 42
Figure 43