Available tests are:
[ prog ] Main board
Mainboard
1.bd
Final
2.Fn
Heat
3.Ht
DSP
4.ds
EEPROM
5.EP
EEPROM Long
6.EP.
Flash
7.FL
Flash Long
8.FL.
MIDI
9.ni
Keyboard
A.yb
Pedal
b.Pd
Leslie
C.LE
Audio
d.AU
[ Live 1 ] Panel board
Panelboard
1.Pn
Button
2.bt
ADC
3.Ad
[ Live 2 ] System
Serial no.
1.Sn
Checksum
2.CS
Erase Flash
3.EF
Clear EEPROM
4.CL
Clavia DMI
Performs test 4,5,7
Only used in production
Only used in production
Tests the two DSP´s, including external memory.
Performs a quick test of the EEPROM.
Tests the entire EEPROM.
Performs a quick test of the Flash circuits.
Flash data is not altered.
Tests the entire Flash memory area.
Flash data is not altered.
Tests MIDI communication. Connect a MIDI cable from MIDI in
to MIDI out and then to Bass Pedal MIDI.
Successful test is presented as O__O
Press one key at a time. Test counts number of keys pressed.
Upper and lower switch is indicated by the dots in the display
Tests the function of the pedal inputs.
To fully test the Rotor control a half moon switch must be used.
Sustain
P pressed
r released
Only used in production
Only used in production
Performs test 2-3
Tests the function of all the buttons
Tests the function of the A/D converter on the panel board.
Knobs incl. swell pedal
Read the serial no. by pressing [on] - [soft] - [fast] - [third]
buttons in the percussion section of the panel board.
Only used in production
Will set all data in Flash to "1"
Will set all data in EEPROM to "0"
Service manual Nord C1 Combo Organ rev. 1.0
Rotor
Swell
F fast
C connected
S slow
Page 5