Specifications

General Features

Input voltage ................................. U
EV connector (EVC-13) ................ SAE J1772 socket, 16 A (type 1, 5P
Internal power consumption .........2 W max.
Operating temperature .................-4 °F to 104 °F (-20 °C to 40 °C)
Storage temperature ....................-4 °F to 122 °F (-20 °C to 50 °C)
Operating humidity range ............. 10 % to 85 % relative humidity
Storage relative humidity ..............0 % to 85 % non-condensing
Operating altitude .........................6561 ft (2000 m) max.
Dimensions (H × W × D) .............. Approx. 8.66 x 4.33 x 1.77 in
Weight ...........................................Approx. 4.4 lb (2 kg)
Safety standards ........................... IEC 61010-1, Pollution Degree 2
Measurement category .................CAT II 250 V
IP protection class ........................IP54

Electromagnetic Compatibility (EMC)

International ................................. IEC 61326-1:
Group 1: Equipment has intentionally generated and/or uses
conductively-coupled radio frequency energy that is necessary for the
internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than
domestic and those directly connected to a low-voltage power supply
network that supplies buildings used for domestic purposes. There
may be potential difficulties in ensuring electromagnetic compatibility in
other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential
environments and may not provide adequate protection to radio
reception in such environments.
USA (FCC) 47 ............................... 47 CFR 15 subpart B. This product is
Functions
CP states ......................................A, B, C, D
CP Error "E" ..................................On/off
PE Error ........................................On/off
GFCI test ...................................... Yes, test resistor of 2 kΩ connected
PE Pre-Test (typical) .....................Visible indication >30 V on PE conductor
Outputs (for test purpose only)
Measuring terminals
L1, L2/N, PE .................................Max. 250 V 50/60 Hz, CAT II 250 V
CP signal output terminals ........... Approx. ±12 V (under normal conditions),
11
= 120 V, U
L1/N
L2/N
60 Hz (three-phase system) or
U
= 120 V, U
L1/N
L2/N
V, 60 Hz (single-phase system), ±10%
voltage fluctuations from nominal
single-phase)
non-condensing
(220 x 110 × 45 mm) without cable
assembly
IEC 61010-2-030
Basic Electromagnetic Environment;
CISPR 11: Group 1, Class A
considered an exempt device per clause
15.103.
between L1 and PE, time limitation 40 ms
in case of wrong wiring or error of the
charging station these terminals can be
hazardous ≥ max. 250 V against PE
= 120 V, U
= 208 V,
L1/L2
= 120 V, U
= 240
L1/L2

Advertisement