NHL-10
Baseband Troubleshooting
Parameter
ADC Gain
ADC Offset
BSI Gain
VBAT Gain
VBAT Offset
VCHAR
ICHAR
IBAT GAIN
Zocus (IBAT) calibration with MJ-2 module jig
Zocus (IBAT) calibration can be performed manually with module jig instead of JBV-1.
Connections
The NHL-10 phone must be placed in MJ-2 (Module jig). Two external power supplies and an
ammeter are needed.
•
Phoenix Setup
•
•
•
•
ISSUE 2 01/2004
Table 2: Calibration value limit
Min.
25400
29000
-50
50
970
1100
10000
11000
2300
2900
58000
62000
4050
4800
0
255
Supply 3.7-4.0 V DC from external power supply to module jig.
Start Phoenix service software.
Select FBUS connection.
Choose Main -> Choose product-> NHL-10.
Choose Tuning -> Zocus EM.
COMPANY CONFIDENTIAL
Copyright © 2003 Nokia. All Rights Reserved.
CCS Technical Documentation
Max.
47