NHL-10
Baseband Troubleshooting
Baseband Tuning operation
Energy management calibration
EM calibration is performed to calibrate the setting (Gain and offset) of AD converters in several
channels (i.e. Battery Size, Battery voltage, Charger voltage, Charger current, Battery Current).
This is to get accurate conversion result of AD converter.
Connections
The NHL-10 phone must be connected to JBV-1 (Docking station) with DA-2 (Docking station
adapter).
•
•
Phoenix Setup
•
•
•
•
ISSUE 2 01/2004
Connect SCB-3 (DC-DC cable) between JBV-1 and charger connector of
phone for charger channel calibration.
Supply 11-16 V DC from external power supply to JBV-1 to power up
phone.
Start Phoenix service software.
Select FBUS connection.
Choose Main -> Choose product-> NHL-10.
Choose Tuning-> Energy Management Calibration.