1. OUTLINE
JCY-1900/1950 VDR Service Manual

1.4. Present and New Model Comparison Table

* In S-VDR, use one of capsules (: NDH-338 or NDH-339).
1) Standard specifications
Item
Capsule
Sensor recording
Audio recording
Image recording
Electric power failure
Operation Panel Unit
Stopping/restarting
recording
Performance test
Microphone test
Alert output
DOC No. 7ZPNA4409
JCY-1900/1950
Fixed Protective Capsule Unit
・48 hours recording
Float-free Capsule Unit
・48 hours recording
Internal storage for long term re-
cording
・720 hours (30 days) recording
(Unremovable)
LAN: 1 port (IEC61162-450, RMS)
Number of connectable units: 24ch
Serial: 24ch
IEC61162-2: 2ch (4800~38400bps)
IEC61162-1: 22ch (4800bps)
Bridge audio (microphone)
6 tracks x 2ch/track = 12ch
(standard)
VHF audio
2 tracks x 2ch/track = 4ch
Input signal: LAN(IEC61162-450)
Number of available inputs: 6
screens
Number of screens for recording:
3 screens (standard)
→ 6 screens are se-
lectable for recording.
Operation continues for 2 hours with
UPS.
* Only bridge audio is recorded dur-
ing power failure.
* After power restoration, VDR au-
tomatically returns to the normal
operation.
Display: LCD (Character display)
Operation: Touch Panel
* Meets the performance test de-
manded.
Operation by the Operation Panel
Unit.
・Ensures security with a password
Checking the latest recorded data is
available through the Operation
Panel Unit.
Automatic test is conducted every 12
hours.
Manual test is available with the Op-
eration Panel Unit.
Output port: Dry contact, serial, LAN
8
JCY-1800/1850
Protective Capsule Unit
・12 hours recording
None
CF card
・12 hours (half day) recording
LAN: 1 port (dedicated for RMS)
Number of connectable units: 24ch
Serial: 32ch
(4800~38400bps)
Bridge audio (microphone)
3 tracks x 3ch/track = 9ch
VHF audio
1 track x 3ch/track = 3ch
Input signal: RGB
Number of available inputs: 2
screens
Number of screens for recording:
1 screen (standard)
→ 2 screens are se-
lectable for recording.
Recording both 2 screens
(option)
Same as JCY-1900
Display: LEDs (Value display)
Operation: Buttons
Error information: 4-digit code dis-
play
Operation by the RCU internal panel.
None
Automatic test is conducted every 12
hours.
Output port: Dry contact

Hide quick links: