2. Slide each flue riser down onto the brackets projecting from the back of the corresponding section(s) of the
sectional range. Secure the flue riser to the brackets with the four provided 1/4-20x3/4 hex-head bolts, flat
washers, and lockwashers. Also, secure the bottom edge of the flue riser to the top rear edge of the sectional
range using the provided #10 sheet metal screws.
3. If access to the interior of the flue riser is necessary to make gas connections, make those connections at this
time.
4. Attach each wall shield to the back of the corresponding flue riser using the provided #10 sheet metal screws.
5. Connect the top side edges of adjoining flue risers using the provided small plates and screws.
6. If tubed shelves were installed, place the tubes in place in the shelf brackets.
7. If sloped enclosures were ordered (for flue-mounted salamander broilers and/or cheese melters), install them at
this time.
S
6: C
E
TEP
ONNECT
A wiring diagram is located behind the kick panel of the oven-base ranges. Be sure that the input voltage and phase
match the requirements shown on the serial plate.
Oven-base ranges ordered with a 115V, 60Hz, single-phase electrical rating are factory-supplied with one or two
three-wire cords (one for each oven), each with a three-prong plug that fits any standard three-prong grounded
receptacle. Each standard oven requires a 15 ampere supply, while each convection oven requires a 20 ampere
supply.
Oven-base ranges ordered with a 208/236V, 60Hz, single- or three-phase electrical rating are factory-equipped with
one or two two-pole terminal blocks (one for each oven), located behind cover plate(s) located on the rear of the unit.
To connect the supply wires, remove the appropriate cover plate. Route the supply wires and the grounding wire
through the strain relief fitting to the terminal block. Insert the supply wires, one each, into the two poles of the
terminal block and tighten the screws. Insert the ground wire into the grounding lug and tighten the screw. Re-attach
the cover plate.
Three phase units are wired as above, using only two supply wires. The third wire is not used and must be properly
terminated.
All units are shipped wired as specified by factory order. Conversion between single-phase and three-phase can be
accomplished by referring to phase loading and line amperes chart on wiring diagram for wire size and ampere
requirements.
S
7: C
G
TEP
ONNECT
If the sectional range is being installed at over 2,000 feet altitude and that information was not specified when
ordered, contact the appropriate authorized Blodgett Range Service Representative or the Blodgett Range Service
Department. Failure to install with proper orifice sizing will result in poor performance and may void the warranty.
The sectional range is design-certified for operation on natural or propane gases. The sectional range is shipped
configured and adjusted for the type of gas specified by the purchaser, which is indicated on the serial plate (see
Figure 1 on page 3). Connect the sectional range ONLY to the type of gas for which it is configured and adjusted.
Minimum supply pressure is 7" W.C. for natural gas, 11" W.C. for propane. An external pressure regulator and shut off
valve are provided. If using a flexible-hose gas connection, the I.D. of the hose must not be smaller than the
connector on the sectional range, and must comply with ANSI Z21.69. Provide an adequate means of restraint to
prevent undue strain on the gas connection.
If applicable, the vent line from the gas pressure regulator shall be installed to the outdoors in accordance with local
codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation
Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for
satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems
and affect burner operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold
pressure. The supply line to the sectional range should be no smaller than the inside diameter of the pipe on the
sectional range to which it is connected.
O
R
ANGE
(
S
LECTRICITY
FOR
ECTIONS WITH
S
AS
UPPLY
'
M
1184743
WNER
S
ANUAL
O
-B
)
VEN
ASES
I
NSTALLATION
P
27
72
AGE
OF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents