Troubleshooting Guide - Hamilton Beach PrimePour COT2000 Series Operation Manual

Hide thumbs Also See for PrimePour COT2000 Series:
Table of Contents

Advertisement

Sanitizing
(cont.)
On the control panel,
5.
verify the spirits valve is
rotated to DISPENSE.
6.
Verify the CO
supply
2
line pressure is between
50 and 60 psi. Connect
the air hose to the
cabinet.

Troubleshooting Guide

Problem . . .
Nothing comes out
when the tap faucet is
opened.
The flow is very slow
when the tap faucet is
opened.
The flow is sputtering
when the tap faucet is
opened.
The flow is only drink
mix when the tap
faucet is opened; no
spirits are dispensed.
The flow is only spirits
when the tap faucet is
opened; no drink mix
is dispensed.
Solution . . .
• Empty drink mix bag in box. The pumps will shut off when the drink mix bag in
box is empty. Connect a new bag in box. Be sure to fully engage the plunger on
the quick connect/disconnect (QCD).
• Low CO
pressure. Open the cabinet door and identify the CO
2
gauge. The unit is designed to operate at 30 psi, and the pressure gauge was set
to 30 psi at the time of the installation. If the pressure gauge is reading less than
30 psi, the CO
tank is likely low or empty. Check the pressure at the CO
2
Replace or recharge if needed. The CO
be between 50 and 60 psi.
• The drink mix bag in box is almost empty. The pumps will shut off when the drink
mix bag in box is empty. Connect a new bag in box. Be sure to fully engage the
plunger on the quick connect/disconnect (QCD).
• Low gas pressure. Open the cabinet door and identify the CO
gauge. The unit is designed to operate at 30 psi, and the pressure gauge was set
to 30 psi at the time of the installation. If the pressure gauge is reading less than
30 psi, the CO
tank is likely low or empty. Check the pressure at the CO
2
Replace or recharge if needed. The CO
be between 50 and 60 psi.
• The quick connect/disconnect (QCD) to the drink mix bag in box is not tight.
Reconnect the QCD to the bag in box. The plunger must be fully depressed.
• Pinched hose. Check for a pinched hose between the cabinet and tap tower.
• Low spirits level. Air in the lines will cause coughing and sputtering at the tap.
Check that there are spirits in the reservoir.
• The drink mix bag in box is almost empty. Check that there is drink mix
remaining in the box. Connect a new box if needed.
• The quick connect/disconnect (QCD) to the drink mix bag in box is not tight.
Reconnect the QCD to the bag in box. The plunger must be fully depressed.
• The spirits shutoff valve is turned OFF. Open
the cabinet door and rotate the handle to
DISPENSE.
• The filter in the spirits reservoir is clogged.
Clean filter. (The mesh filter is located in the
bottom of the spirits reservoir.)
• The flow control orifice is clogged. Remove
and clean the flow control orifice. The flow
control orifice is located between the pumps
and secured to the side wall of the cabinet.
• The drink mix BIB is almost empty. Connect a new bag in box.
• The quick connect/disconnect (QCD) to the drink mix BIB is not tight. Reconnect
the QCD to the bag in box. The plunger must be fully depressed.
Pump the sanitizing solution through the
7.
system by opening the tap handle. When
sanitizer is flowing freely at the tap, close the
tap and allow the solution to work for
5 minutes.
Flush with clean water and pump until the
8.
spirits reservoir is empty.
Install the cover to the spirits reservoir.
9.
supply line leading to the cabinet should
2
supply line leading to the cabinet should
2
Mesh Filter
pressure from the
2
tank.
2
pressure from the
2
tank.
2
7