Hamilton Beach PrimePour COT2000 Series Operation Manual page 6

Hide thumbs Also See for PrimePour COT2000 Series:
Table of Contents

Advertisement

Installation
(cont.)
Fold the tip of the bottle nozzle
17.
over, and insert the nozzle into
the spirits reservoir, tilting the
bottle upside down. Lower the
bottle holder and secure by
tightening the thumbscrew.
Slide the drawer into the
cabinet after the spirits bottles
are installed. The bottle holders need to be centered
on the bottoms of the bottles. If the bottle holders
hit the cabinet when sliding the drawer inside, then
adjust the position of the holders on the bottoms of
the bottles.
18.
Install the bag in box (BIB) by
opening the end of the box
and pulling out the fitting.
A cap is installed over the
fitting; pull to remove. Slide
the fitting into the slot of the
cardboard box. Slide the box
into the unit.
Fully pull out the
19.
plunger on the quick
connect/disconnect
(QCD). Attach the QCD
by sliding it over the
fitting. Firmly push in on
the plunger to engage the
fitting, and slide the BIB
into the cabinet as far as
it will go.
Sanitizing
Prepare the sanitizing solution by mixing
1.
1.24 ounces (1.5 teaspoons or 7.5 ml) 5%
liquid chlorine (liquid bleach–unscented,
nondetergent, non-drip-free, fresh new product)
in one gallon of water, resulting in a 100 ppm
concentration.
Remove the cover to
2.
the spirits reservoir by
loosening and removing
the six screws. Remove
the bottle nozzles. If
the reservoir cover
has plugs in each of
the holes, remove and discard the blue plugs.
Immerse the bottle nozzles in the sanitizing
solution. With a soft brush, brush the inside and
outside of the cover with sanitizing solution,
and rinse with clear water. Remove the bottle
nozzles from the sanitizing solution and rinse
with clear water.
6
On the control panel,
20.
verify the spirits valve is
rotated to DISPENSE.
There may be sanitizer or
21.
water in the hoses if it was
just sanitized. Dispense
about 12 ounces (355 ml)
or until air is no longer
trapped in the lines.
22.
Check fittings and hoses for signs of pinching
and leaking. Adjust and tighten where needed.
Check the pressure gauge again to confirm it
indicates 30 psi.
Install the side access
23.
panel and front door.
Push the cabinet into
24.
position, verifying the
hoses do not get pinched.
25.
Open and close the
front door to verify it
travels freely.
26.
Pull and push in the spirits reservoir drawer to
verify it travels freely.
27.
Sample a drink to ensure the integrity of
the product. The unit is calibrated at the factory
to dispense at a ratio of 3 parts drink mix to 1
part spirits.
Fill the spirits reservoir
3.
with about 25 oz.
(739 ml) of sanitizing
solution. Using a soft
brush, brush the top
portion of the inside of the spirits reservoir.
Attach the bag-in-box
4.
(BIB) cleaning connector
to the quick connect/
disconnect (QCD) by
sliding it into position
and depressing the
plunger. Immerse the
QCD in a bucket of
sanitizing solution.

Advertisement

Table of Contents
loading

Table of Contents