User Manual Wine Cellar Cooling System Self-contained Thenow Australia Thank you for purchasing this “Thenow”product; PO Box 107 Please read this manual carefully before attempting Park Orchards Vic 3114 to install,operate or service; Please retain this booklet for future reference.
Table of Contents WARNING To avoid the risk of electrical shock ,property damage ,personal injure or death,please read the following instructions carefully with safety or warning labels. During transportation or moving, please follow the Introduction correct direction on the packing case. * After transportation or moved, it needs to be allowed to stand for more than 24 hours before it can be turned on.
Introduction Working Principle Thenow wine cellar cooling self-contained unit best suited to the 1.Refrigeration wine room and wine cabinet.The device is suitable for wine cabinets Using cycling vapor compression refrigeration system,when the or wine storage rooms below 5m³. The purpose of this device is to...
( ) Dimensions HSN-J15-Z Side Supply Air/Top Return Air Main Technical Datas Unit Dimension Dimensions HSN-JC3: Unit:mm ( ) Dimensions HSN-J15-Z Side Supply Air/Bottom Return Air Unit:mm www.thenowair.com.au www.thenowair.com.au...
Technical Datas Installation & Debugging 1. Pre-installation Inspection (1) Check the outer packing for breakage. (Up to ) (2) Machine model (nameplate), check whether it is consistent with what you ordered. (3) The appearance of the whole machine is intact (...
Page 7
Installation Conditions HSN-JC3 HSN-J15-Z Side Supply Air/Top Return Air (1) Place the wine cabinet in a properly ventilation location. Otherwise,heat exhausted by the cooling unit will build up and it will not operate properly. (2) Equipment should install on horizontal ground or platform, tilt angle must not exceed one degrees, platform or ground should be able to load-bearing unit weight.
Page 8
Installation Conditions HSN-J15-Z B. Wine Room Installation (1) Place the wine cabinet in a properly ventilation location. Otherwise,heat exhausted by the cooling unit will build up and it will not operate properly. (2) Equipment should install on horizontal ground or platform, tilt angle must not exceed one degrees, platform or ground should be able to load-bearing unit weight;...
Wiring Schematic 1. Online Debugging HSN-JC3 & HSN-J15-Z PCB Wiring Schematic Note:The bottom of the equipment must be fixed with an expansion bolt, and ground connection has to be completely correctly. Confirm...
Functional features: Introduction And Use of the Control Panel 1. With 4-inch capacitive full-touch screen to display clear texture. 2. Temperature and humidity ,clock real time display . 3. Can be controlled regularly. 4. Wind speed manual/automatic control selection. 5. Multiple operating mode options. 6.
Page 11
Schematic diagram of electrical connection: Use the steps Description: Please connect in strict accordance with the product wiring diagram ,wiring must be disconnected from the power supply ,if any abnormality occurs ,please cut off the power supply and contact the manufacturer as soon as possible.
Schematic diagram of electrical connection Maintenance 1.Using Requirements (1) Working conditions: Surrounding temperature at 5℃-35℃, relative humidity lower than 90% ; (2) Please make certain power supply is specified voltage, it's strictly prohibited to operate equipment with phase missing or under voltage;...
Do not replace the filter while the machine is working Troubleshooting Status Reason Suggestion 1. No power. 1. Check power at receptacle &fuses. 2. power cord unplugged. 2. Plug-in power cord plug. 3. low voltage 3. Contact an authorized electrician. Troubleshooting 4.
The above information is for reference only. If the machine fails to work Status Reason Suggestion properly, please contact your local dealer or your local authorized repair station. 1. Setting too high. 1. lower setting. All electrical installation and maintenance work in this manual must be 2.