Viewing Data (During Ventilation) - ResMed VS III User Manual

Hide thumbs Also See for VS III:
Table of Contents

Advertisement

4.3 Viewing data (during ventilation)

9
cm
H2O
60
50
40
30
20
10
0
12
H2O
cm
60
50
40
30
20
10
0
Figure 14: Viewing data
The following figure shows the screens for each option:
Ventilation settings and alarm thresholds:
0
PS
H2O
cm
PEEP 4
60
50
fmin
40
Rise t
30
20
Vts
10
0
Measurements:
10
f = 15 bpm
H2O
cm
I:E = 1:2.3
60
50
Ti = 1.00 s
40
30
Vti = 0.60 L
20
10
MV
0
Event and Alarm Log:
DATE & TIME
0
28/06/2011 18:38:48
H2O
cm
28/06/2011 18:54:40
60
27/06/2011 09:52:43
50
25/06/2011 08:13:03
40
24/06/2011 11:06:22
30
23/06/2011 09:52:23
20
22/06/2011 10:32:03
10
21/06/2011 19:55:54
0
Events #1 to 8 of 17
Figure 15: Information screens (examples)
For any further information, please contact your HME provider.
14
27/08/2008 17:20
PS.Vs
Stop
PS.Vs
Menu
View settings/alarms
View Monitoring
Technical information
Events/Alarms Log
Back
PS.Vs
View settings
TgI(P) AUTO
10
cmH2O
TgI(V) NO
cmH2O
TgE
AUTO
15
bpm
Timin 0.3
2
s
0.50
Timax 2.0
L
s
: Alarm thresholds
PS.Vs
View Monitoring
FiO2 = 21 %
Leaks = 0 %
= 9.0 L/min
I
27/06/2011 16:48
ALL EVENTS
CODE
21
High FiO2:%FiO2:
25
High FiO2:%FiO2:
21
Low FiO2:%FiO2:
01
Start of ventilation: prog:
3
Loss of power supply:
2
Switched to internal battery:
1
Switched to external supply:
0
Switched to mains supply:
/
: Scroll
: Alarms only
With the main screen displayed, press
1
to access the "Menu" screen.
Use
to select the option you wish to
2
display:
the ventilation settings and alarm
thresholds;
the measurements (monitoring);
the technical information or;
the Event and Alarm Log, then press
to confirm.
PS.Vs
View alarm thresholds
0
min
max
H2O
cm
f
--
20
60
50
40
Vt
0.25
0.80
30
20
FiO2
21
100
10
0
Technical information:
27/08/2008 16:49
0
Patient hours= 1650h
H2O
cm
Machine hours= 2000h
60
50
Turbine wear= 0%
40
30
Circuit type= Valve
20
10
Software version= x.xx
0
27/06/2011 16:49
DATE & TIME
ALARM EVENTS
0
28/06/2011 18:38:48
High FiO2:%FiO2:
H2O
cm
28/06/2011 18:54:40
High FiO2:%FiO2:
60
27/06/2011 09:52:43
Low FiO2:%FiO2:
50
20/06/2011 08:13:03
Mains supply
40
20/06/2011 08:13:20
Mains supply
30
13/06/2011 09:52:23
Patient disconnection
20
13/06/2011 09:52:30
Patient disconnection
10
01/06/2011 19:55:54
External battery
0
Events #1 to 8 of 11
/
: Scroll
bpm
L
%
: Settings
CODE
21
25
21
--
--
--
--
--
: All events

Hide quick links:

Advertisement