Trouble Codes
12/05
Code
Part or System
Rail Pressure Governor
P0088
Deviation
Rail Pressure Governor
P0089
Deviation
Fuel Pressure Control Valve
P0090
Rail Pressure Governor
Deviation
P0091
Fuel Pressure Control Valve
P0092
Fuel Pressure Control Valve
Charge Air Temp
P0112
Charge Air Temp Sensor
Charge Air Temp
P0113
Charge Air Temp Sensor
P0117
Coolant Temp Sensor
P0118
Coolant Temp Sensor
Throttle Signal
P0122
Throttle Signal
Throttle Signal
P0123
Throttle Signal
P0182
Fuel Temperature Sensor
P0183
Fuel Temperature Sensor
P0192
Fuel Rail Pressure Sensor
P0193
Fuel Rail Pressure Sensor
P0201
Injector No. 1
P0202
Injector No. 2
P0203
Injector No. 3
P0204
Injector No. 4
P0205
Injector No. 5
P0206
Injector No. 6
Throttle Signal
P0222
Throttle Signal
Throttle Signal
P0223
Throttle Signal
P0230
Fuel Feed Pump
P0231
Fuel Feed Pump
P0232
Fuel Feed Pump
BY Service Manual
Mode
Fuel rail pressure out of range
Fuel rail pressure out of range
Not connected
Fuel rail pressure out of range
Short circuit to Ground
Short circuit to B+
Over 125°C (257°F)
Short circuit to B+
Under -20°C (-4°F)
No connection / short circuit to Ground
Short circuit to B+
No connection / short circuit to Ground
Both throttle signals are missing / short circuit to
Ground
Throttle signal 1 is missing / short circuit to Ground
Both throttle signals are short circuited to B+
Throttle signal 1 short circuit to B+
Short circuit to B+
No connection / short circuit to Ground
Short circuit to Ground
No connection / short circuit B+
Open circuit / short circuit to Ground
Open circuit / short circuit to Ground
Open circuit / short circuit to Ground
Open circuit / short circuit to Ground
Open circuit / short circuit to Ground
Open circuit / short circuit to Ground
Both throttle signals are missing / short circuit to
Ground
Throttle signal 2 is missing / short circuit to Ground
Both throttle signals are short circuited to B+
Throttle signal 2 short circuited to B+
Not connected
Short circuit to Ground
Short circuit to B+
© 2009 Yanmar Marine International
T R O U B L E S H O O T I N G
Run Or
Check
Engine
Conditi
Engine
Can Start
on
Alarm
reduce or
depends
alarm
shut off
on fault
yes
yes
alarm
no
no
alarm
reduce
yes
alarm
reduce
yes
alarm
no
no
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
1600
yes
alarm
reduce
yes
alarm
1600
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
reduce
yes
alarm
1600
yes
alarm
reduce
yes
alarm
1600
yes
alarm
reduce
yes
alarm
no
no
alarm
reduce
yes
alarm
no
no
alarm
13-11