Replace Charge Air Pressure Sensor; Replace Charge Air Temperature Sensor - Yanmar BY Series Service Manual

Marine engines
Hide thumbs Also See for BY Series:
Table of Contents

Advertisement

Repair
12/05

Replace Charge Air Pressure Sensor

1. Disconnect battery negative (-) cable.
2. Disconnect electrical connector
(Figure 12-25, (1)).
Figure 12-25
Figure 12-25
3. Pull sensor out of charge air pipe.
4. Install new sealing ring (Figure 12-26, (1))
before installing sensor (Figure 12-26, (2)).
Figure 12-26
Figure 12-26
5. Install sensor and connect electrical connector.
6. Connect battery negative (-) cable.
7. Check and delete any trouble codes that are
registered in the ECU after the work has been
completed.
BY Service Manual
Replace Charge Air Temperature
Sensor
1. Disconnect battery negative (-) cable.
2. Disconnect electrical connector
Figure 12-27
( 1 )
3. Remove sensor from charge air pipe.
4. Replace sealing ring before installing sensor.
5. Install sensor and tighten to 7 N·m (62 in.-lb.).
6. Connect battery negative (-) cable.
7. Check and delete any trouble codes that are
© 2009 Yanmar Marine International
ELECTRICAL AND ECU
(Figure 12-27, (1)).
( 1 )
Figure 12-27
Connect electrical connector.
registered in the ECU after the work has been
completed.
12-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4by26by2

Table of Contents