2.6
Technical characteristics
Technical characteristics
Gas Consumption
Nominal Gas Consumption
Ø burner injector
Supply pressure flowing
Natural gas (When operating)
LP gas (When operating)
Number of injectors
Water data
Maximum permissible pressure (Static)
Temperature selector in fully clockwise position
Temperature rise (Above incoming water temperature)
Water flow range (Litres per minute)
Minimum operating water pressure
Minimum constant water pressure for minimum flow
Temperature selector in fully anti-clockwise position
Temperature rise (Above incoming water temperature)
Water flow range (Litres per minute)
Minimum operating water pressure
Minimum constant water pressure for maximum flow
Table 5
Pilot Ignition – 6 720 886 398 (2021/02)
Technical Characteristics and Dimensions
Units
TF250...
MJ/h
82
mm
1.20 (NG)
0.75 (LPG)
kPa
1.13
kPa
2.6
12
kPa
1200
°C
55
l/min
3.5 to 4.5
kPa
30 (NG)
10 (LPG)
kPa
60
°C
25
l/min
4 to 10
kPa
45
kPa
90 (NG)
55 (LPG)
TF400...
130
1.30 (NG)
1.13
2.6
18
1200
_
_
_
_
_
_
_
_
_
7