Requirements Of The Installation; Location - Bosch Pilot Ignition TF250 Series Installation Manual And Operating Instructions

Continuous flow gas water heater
Hide thumbs Also See for Pilot Ignition TF250 Series:
Table of Contents

Advertisement

Installation
4.2
Requirements of the installation location
Comply with the specific instructions for each State.
Install the appliance in an outdoor location where it will not
be exposed to temperatures below zero.
Install the appliance in accordance with the minimum
installation clearances indicated in Fig. 4, according to
AS/NZS5601.
The gas heater must not be installed over a heat source.
Fig. 4
Minimum clearances (use as a guide only, always refer to AS/NZS5601)
[D] Openable Door
[T] Flue terminal
[M] Gas meter
Ref. Item
a
Below eaves, balconies and other projections:
- Appliances over 50 MJ/h input
b
From the ground, above a balcony or other surface
c
From a return wall or external corner
Table 6
10
I
c
a
k
j
D
h
b
T
P
1)
Location must allow for safe servicing and customer
operation.
Side clearances to be measured from flue outlet, not wind
baffles.
Do not obstruct the openings at top, bottom and rear of
appliance.
Maximum of 2 meters from the ground to the base of the
appliance.
Top and bottom areas must be clear from any obstacles at
least 30 cm.
j
W
d
n
f
e
[I]
Mechanical air inlet
[P] Electricity meter or fuse box
[W] Openable window
1)
T
g
M
Pilot Ignition – 6 720 886 398 (2021/02)
9708069951-14.2V
Minimum
clearances (mm)
500
300
500

Hide quick links: