Installation
4.2
Requirements of the installation location
•
Comply with the specific instructions for each State.
•
Install the appliance in an outdoor location where it will not
be exposed to temperatures below zero.
•
Install the appliance in accordance with the minimum
installation clearances indicated in Fig. 4, according to
AS/NZS5601.
•
The gas heater must not be installed over a heat source.
Fig. 4
Minimum clearances (use as a guide only, always refer to AS/NZS5601)
[D] Openable Door
[T] Flue terminal
[M] Gas meter
Ref. Item
a
Below eaves, balconies and other projections:
- Appliances over 50 MJ/h input
b
From the ground, above a balcony or other surface
c
From a return wall or external corner
Table 6
10
I
c
a
k
j
D
h
b
T
P
1)
•
Location must allow for safe servicing and customer
operation.
•
Side clearances to be measured from flue outlet, not wind
baffles.
•
Do not obstruct the openings at top, bottom and rear of
appliance.
•
Maximum of 2 meters from the ground to the base of the
appliance.
•
Top and bottom areas must be clear from any obstacles at
least 30 cm.
j
W
d
n
f
e
[I]
Mechanical air inlet
[P] Electricity meter or fuse box
[W] Openable window
1)
T
g
M
Pilot Ignition – 6 720 886 398 (2021/02)
9708069951-14.2V
Minimum
clearances (mm)
500
300
500