Lennox ELITE Series Installation Instructions Manual page 58

Upflow / horizontal air discharge
Table of Contents

Advertisement

Blower Data
EL296UH110XE60C PERFORMANCE (Less Filter)
Bottom Return Air, Side Return Air with Return Air from Both
External
Sides or Return Air from Bottom and One Side.
Static
Pressure
in. w.g.
High
Med-High
(Black)
(Brown)
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00
2220 645 1940 435 1765 335 1635 280 1435 200 2185 655 1915 440 1745 340 1620 275 1430 195
0.10
2170 660 1920 460 1715 350 1595 290 1380 205 2160 660 1880 460 1705 345 1570 285 1380 205
0.20
2130 680 1865 475 1670 370 1560 305 1345 220 2115 680 1835 470 1670 365 1535 305 1325 220
0.30
2095 700 1835 490 1640 390 1525 325 1285 230 2060 705 1795 495 1630 380 1505 320 1285 230
0.40
2065 720 1785 510 1600 405 1465 335 1250 245 2050 720 1760 510 1570 400 1455 330 1235 245
0.50
2030 740 1755 525 1560 415 1425 355 1215 260 2000 740 1720 530 1535 415 1410 345 1195 260
0.60
1995 760 1705 550 1525 435 1380 370 1150 270 1955 760 1685 550 1505 435 1380 365 1145 275
0.70
1955 770 1660 560 1475 450 1350 375 1100 290 1935 775 1650 555 1455 450 1325 375 1100 285
0.80
1930 790 1635 575 1445 460 1300 395 1050 305 1890 790 1610 575 1425 460 1285 390 1055 295
EL296UH135XE60D PERFORMANCE (Less Filter)
Bottom Return Air, Side Return Air with Return Air from Both
External
Sides or Return Air from Bottom and One Side.
Static
Pressure
in. w.g.
High
Med-High
(Black)
(Brown)
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00
2405 940 2235 735 2070 545 1830 390 1620 280 2395 925 2235 710 2020 550 1800 380 1610 275
0.10
2365 960 2210 745 2020 565 1770 400 1585 295 2360 935 2175 735 2005 555 1760 395 1550 295
0.20
2330 975 2180 770 1950 580 1745 420 1535 315 2350 955 2160 760 1955 565 1725 415 1510 300
0.30
2295 1000 2120 785 1925 595 1690 435 1480 325 2290 990 2095 775 1890 590 1700 435 1420 325
0.40
2275 1015 2075 805 1885 615 1640 460 1445 340 2255 995 2060 795 1850 615 1635 445 1390 340
0.50
2225 1025 2035 815 1845 630 1605 475 1395 360 2230 1010 2040 815 1845 625 1590 470 1375 360
0.60
2185 1010 2020 835 1815 645 1565 485 1330 365 2170 1025 2000 820 1795 640 1580 485 1335 370
0.70
N/A
N/A 1940 850 1735 665 1520 500 1310 385
0.80
N/A
N/A 1890 860 1715 680 1465 510 1285 400
Air Volume / Watts at Different Blower Speeds
Medium
Med-Low
Low
(Blue)
(Yellow)
(Red)
Air Volume / Watts at Different Blower Speeds
Medium
Med-Low
Low
(Blue)
(Yellow)
(Red)
Page 58
Single Side Return Air − Air volumes in bold require
Optional Return Air Base and field fabricated transition to
accommodate 20 x 25 x 1 in. air filter in order to maintain
proper air velocity.
High
Med-High
Medium
(Black)
(Brown)
Single Side Return Air − Air volumes in bold require
Optional Return Air Base and field fabricated transition to
accommodate 20 x 25 x 1 in. air filter in order to maintain
proper air velocity.
High
Med-High
Medium
(Black)
(Brown)
N/A
N/A 1935 845 1725 660 1520 500 1295 385
N/A
N/A 1880 855 1705 680 1470 510 1260 405
Med-Low
Low
(Blue)
(Yellow)
(Red)
Med-Low
Low
(Blue)
(Yellow)
(Red)

Hide quick links: