Lennox ELITE Series Installation Instructions Manual page 24

Upflow / horizontal air discharge
Table of Contents

Advertisement

Maximum Allowable Exhaust Vent Pipe Length (in ft.) Without Insulation In Unconditioned Space For
Winter Design
Temperatures1 °F
(°C)
32 to 21
(0 to -6)
20 to 1
(-7 to -17)
0 to -20
(-18 to -29)
1Refer to 99% Minimum Design Temperature table provided in the current edition of the ASHRAE Fundamentals Handbook.
2 Poly-Propylene vent pipe (PP) by Duravent and Centrotherm.
NOTE - Concentric terminations are the equivalent of 5' and should be considered when measuring pipe length.
NOTE - Maximum uninsulated vent lengths listed may include the termination(vent pipe exterior to the structure) and cannot exceed
5 linear feet or the maximum allowable intake or exhaust vent length listed in TABLE 5 or TABLE 6 which ever is less.
NOTE - If insulation is required in an unconditioned space, it must be located on the pipe closest to the furnace. See FIGURE 31.
Winter Design Temperatures Two - Stage High Efficiency Furnace
Vent Pipe
Diameter
045
PVC
2 in
21
2-1/2 in
16
3 in
12
2 in
11
2-1/2 in
7
3 in
2
2 in
6
2-1/2 in
1
3 in
1
Conditioned
Space
TABLE 7
Unit Input Size
070
PP
PP
PVC
PVC
2
2
18
33
30
n/a
26
n/a
12
21
21
9
19
17
n/a
14
n/a
2
9
9
4
12
10
n/a
7
n/a
1
2
2
Conditioned
Space
Pipe Insulation
Unconditioned
Space
FIGURE 31
Page 24
090
110
PP
PVC
2
2
46
42
30
37
n/a
36
n/a
30
30
29
28
25
27
21
n/a
20
n/a
16
16
14
19
16
18
13
n/a
12
n/a
8
8
7
Exhaust
Pipe
Intake
Pipe
135
PP
PP
PVC
2
30
n/a
n/a
n/a
n/a
29
42
42
24
n/a
n/a
n/a
n/a
14
23
23
15
n/a
n/a
n/a
n/a
7
13
13