APE Clocking
APE clocks
trouble
shooting
Clk32k (J4815):
Voh ~ 2.8V &
f ~ 32.768kHz ?
(Figure 1)
Yes
12Mhz clock
(C4800, OSC1_IN):
Vpp ~ 1.7V &
f ~ 12.0MHz ?
(Figure 3)
Yes
Check completed
Issue 1 11/2004
SleepClk ( J2802):
Voh ~ 1.8V &
No
f ~ 32.768kHz ?
(Figure 2)
No
Check that
(C4800, OSC1_IN)
DC-offset ~ 720mV
No
(C4802, OSC1_OUT)
DC-offset ~760mV
(Figures 3&4)
Yes
Solder joints of
C4800, C4801,
C4802 and B4800
OK ?
Yes
Measure
resistance over
No
C4801.
R >>1M ?
Yes
Change B4800. If
this doesn't help,
change C4800,
C4801 and C4802.