Nokia Customer Care
Steps
1. Cover the light guide (upper part of the A-Cover).
Phoenix .
2. Start
3. Choose File→Scan Product.
4. Choose Tuning→Ambient Light Sensor Calibration.
Pull Up Resistor Calibration pane, click Start, and Write.
5. In the
Ambient Light Sensor Calibration pane, check the Use default values only check box, and click
6. In the
Write.
7. To end the calibration, click Close.
Page 6 –26
Ambient Light Sensor Calibration window
Figure 36
COMPANY CONFIDENTIAL
Copyright © 2006 Nokia. All rights reserved.
BB Troubleshooting and Manual Tuning Guide
RM-88