Controller Serial Connection - Siemens Stratos Outstation General, Installation, Commissioning & Maintenance Handbook

Hide thumbs Also See for Stratos Outstation:
Table of Contents

Advertisement

The other boards in the system are powered over the RJ45 GSPI cables.
It is important that only supplied RJ45 cables are used as the cable must
carry all of the supply current. (Certain cheaper RJ45 cables are known to
have very thin conductors which will cause a problem if used on a Stratos
Outstation).
5.6

Controller Serial Connection

The Stratos Outstation can be connected to the TR 2523 port of a traffic controller using
the correct RS232 interface cable and baud rate as shown in the tables below:
Supplier
Controller
Siemens
ST950
ST800
ST900
ST750
ST700
T400
T500
Microsense /
MPC
Telent
MTC
Sentinel
Optima
Peek
TSC3
TRX
PTC-1
TSP
Motus
TM150
TM150 2P
* This baud rate can be set by the BDR handset command.
Table 24 – Controller RS232 Baud Rates and Cable Variants
RS232
Description
Cable
Standard
This is a 1.6 metre cable for controllers which drive
hardware flow control signals DTR & RTS. The cable
terminates in 25-way D-type plug.
This cable is supplied as standard with the outstation.
Security classification
Unrestricted
Version
3
Last Editor
Alan Doyle
Document Name
Stratos Outstation General and ICM Handbook
Copyright © Siemens plc 2014. All Rights Reserved.
RS232 Baud Rate
19200
19200
19200
19200
19200
1200
1200
1200
1200
1200
1200
1200 (19200*)
9600 (19200*)
9600 (19200*)
1200 (19200*)
115200
115200
Mobility and Logistics is a division of Siemens Plc
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
RS232 Cables (see Table 25)
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard + Extension
Standard + Extension
Standard
Loopback
Loopback
Loopback
Loopback
Loopback
Loopback
Loopback
Part Number
667/1/47176/100
Page
60 of 92
Status
Issued
Date
05-Oct-2017
Document No.
667/HB/52250/000