Fault
Unrecognised hardware
Software error
(includes – Checksum failure, Watchdog
Failure, S/W general error, Initialisation
failure)
GSPI Address Changed
4.8.3

Connector Pinouts

The I/O card pinout is the same as that on the Gemini
board allowing for direct replacement.
When making custom I/O looms remember that the connector shell is
actually 54 ways with the two end positions unused as shown below. (To
allow the connector to be retained by the latching arms).
49
Top
50
49
Bottom
50
Security classification
Unrestricted
Version
3
Last Editor
Alan Doyle
Document Name
Stratos Outstation General and ICM Handbook
Copyright © Siemens plc 2014. All Rights Reserved.
Table 19 – I/O board fault troubleshooting
End Connector Socket Positions Not Used
Figure 14 – I/O Board Connector Pinout
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Possible cause/Remedy
Unable to interface with the EEPROM device
on startup. Hardware error.
- replace the PSU board.
Unlikely to occur. If observed report to Poole
Engineering (see section 1.2)
- Power cycle the Gemini3 unit if possible – to
attempt to remove the fault.
The board address has changed, but the new
address will not take effect until the next board
reset. All board addresses should be set as
desired and then the whole system power
cycled.
25
26
25
26
Page
Status
Date
Document No.
Mobility and Logistics is a division of Siemens Plc
2
Bus/MOVA I/O
1
2
1
2
47 of 92
Issued
05-Oct-2017
667/HB/52250/000