Troubleshooting - Rinnai CAH Series Instalation And Operating Manual

Advertisement

Menu
Parameter
Configuration Language
AC/HP Tons
CFM/TON
Cooling/HP
Dehum ON State Set the active state of the DH signal
Dehum Ratio
AC Y1 Ratio
Cont Fan Ratio
Heat Fan Ratio
Fan
Fan W1 Ratio
Heat Off Ratio
Recirculation
W1 Ratio
Pump
Purge Cycle
Purge Ratio
AC/HP On
AC/HP Off
Delays
Heat On
Heat Off
(1)
Ratio in percentage of max airflow (Y2)
(2)
Ratio in percentage of max airflow of 1600 CFM
(3)
Ratio in percentage of max hydronic heating airflow (W/W2)
(4)
Ratio in percentage of heating airflow (W1 or W2)
(5)
Reduce the value if the water heater activates during the purge cycle

TROUBLESHOOTING:

Insufficient or no heat:
Check filter, replace if dirty
Verify the hydronic coil is not clogged.
Verify there no air trapped in the heating loop. Purge the loop if air is present.
Verify Rinnai Engine operation and water temperature. Clean inlet water filter on Rinnai engine.
Verify there are no restrictions in the heating loop. Verify all valves are fully open and functional.
The pump does not run:
Verify 120V power is present to the pump
Hard water may cause the pump to seize. Recirculation mode will prevent pump seizing.
The pump is noisy at start-up:
Purge the hot water loop of air.
Heating during the fan on mode:
Verify the check valve in the heating circuit is present and is not stuck.
40
Switch between English and French
Set the cooling/heat pump capacity (Tons)
Airflow adjustment per ton of cooling (CFM)
(1)
Dehumidification cooling fan ratio
(1)
Fan ratio for 1st cooling stage
(1)
Continuous Fan Ratio
(1)
Fan ratio in heating mode (W/W2)
(2)
Fan ratio for 1st heating stage
(1)
Fan ratio during off delay
Time between recirculation (hours)
Pump ratio for 1st heating stage
Time during the pump will operate after a call
for heating
(5)
Pump activation frequency during purge cycle
Fan delay when heat pump starts
Fan delay when heat pump stops
Fan delay when engine starts
Fan delay when boiler stops
Canadian Air Handler Installation and Operation
Description
Min
Max
Default
-
-
English
0
10
0
300
500
400
LOW HIGH
HIGH
50% 100%
85%
50%
90%
70%
15% 100%
50%
35% 100%
75%
45% 100%
50%
0%
100%
40%
OFF
48
24
1%
100%
13%
240
1 sec
1 sec
sec
1%
100%
6%
5
120
5
5
240
90
5
120
5
0
240
120

Advertisement

loading