7.

Installer Configuration Menu

From the Home Screen: Press Menu, then the Installer Config touch key and hold for 5 seconds. The Screen Reference number appears
in the top right corner of display. See reference numbers in the table below. Screen Reference numbers appear in top right corner of
display. Press
to advance to the next menu item or
Shaded items are not available if selected for Non-Programmable. Write the options selected in the "Option Selected" column of the menu.
Installer Note: To default the programming, clock and Configuration Menu to the Factory Default Settings, press the
keys simultaneously. The thermostat display will go blank for a few seconds, and then all segments will display momentarily. For heat
pump systems, Configuration Menu items 1 and 3 must be set to match the heat pump system.
302
303
Screen Reference
SS1
Number
MS2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
14
to return to a previous menu item. Press
Displayed
HP1
Press
Factory
HP2
key
(Default)
MS 2
HP 1, HP 2, SS 1
(gas)
0b (0)
Days, (7) P
(4) PS
Cool-Off-Heat, Heat
Cool-Off-
Off, Heat, Cool-Off,
Heat-Auto
Cool-Off-Heat-
Cool-Off-Heat-Em,
Em-Auto
(On) E
(FA) Heat, Cr
(FA) Cool, Cr
(FA) Cr/AU,
Em
(OFF) SC
(OFF) CL
(OFF) dL
0
(Temperature)
°F
(On) b
(On) dS
(On) Heat, AS
(On) Cool, AS
(OFF) CS
CS Cool
Savings (3)
(Off) CO
(OFF) CA
(99) Heat, HL
CONFIGURATION MENU
Press
or
to select from
listed options
Selects Multi-Stage (MS2, No Heat Pump), Heat Pump 1
(HP1, 1 compressor), Heat Pump 2 (HP2, 2 compress or
2 speed compressor), or Single Stage.
GAS setting: furnace controls blower.
ELE
ELE setting: thermostat controls blower.
Selects Reversing Valve
b
(This item is only to appear if HP1 or HP2 is selected
above.)
Programs per week. (7 days, 5+1+1 days or non-
5 or 0
programmable)
Programs per day.
4 = Morning, Day, Evening, Night
2
2 = Day, Night
Not available if 4 is 0
System switch configuration in non heat pump mode.
Auto Off
System switch configuration, heat pump mode.
Off-Em-Auto
Selects Energy Management Recovery. Not available if 4
OFF
is 0
SL
Selects Adjustable Anticipation, cycle rate, Heat
SL
Selects Adjustable Anticipation, cycle rate, Cool
Selects Adjustable Anticipation, cycle rate auxiliary,
SL
(This item is only to appear if HP1 or HP2 is selected
above).
ON
Selects Stage Cycle Completion On (Off).
Compressor Lockout. Default minimum OFF Time = 5
On
minutes
On
Selects Continuous Display backlight.
Selects Adjustable Ambient Temperature
5, LO to 5, HI
Display [range -5 (LO) to +5 (HI)].
Selects °F/°C Display (temperature units in Fahrenheit or
°C
Celsius).
OFF
Selects audible Beeper On/Off.
OFF
Selects Daylight Saving Time calculation.
Selects Automatic Schedule for comfort temperature
OFF
Programming, heat mode. Not available if 4 is 0
Selects Automatic Schedule for comfort temperature
OFF
Programming, cool mode. Not available if 4 is 0
On
Selects Cool Savings Feature On of Off.
1-2-3-4-5-6
Selects amount of Cool Savings adjustment.
On
Select Compressor Optimization
On
Selects Comfort Alert Feature On or Off
62-98
TEMPERATURE LIMIT, HEAT (max. heat set point).
Part No. 37-7760003
or
to change a menu item option.
,
and SYSTEM
Comments
09-2018 18-HD48D1-1A-EN
Option
Selected