Problem Areas: Network & Signal
Check:
Inspect the connector of the RF Cable to the Sub Board
Assy.
Action:
1. If not properly connected – disconnect and reconnect it.
2. If the connector or the pins of the Sub Board Assy is
damaged – replace the Sub Board Assy.
Check:
Inspect the connector of RF Cable to the PBA.
Action:
1. If not properly connected – disconnect and reconnect it.
2. If the RF Cable or its two connectors is damaged –
replace the RF Cable.
3. Replace board.
1266-5137 Rev 2
Sony Mobile Communications AB – Company Internal
Troubleshooting Guide (mech)
36(43)