2118 (RH-77)
RF Description and Troubleshooting

Rx RF

The following Rx RF Troubleshooting table indicates the test points to probe when
troubleshooting the Rx RF. It is recommended that you follow the steps in order. See
Figure 18
on page
Step #
Part
R1
L802R (Top
side of the
PWB)
R2
L906L
R3
C903L
R4
Z901-R-
Bottom,
N901-Pin16
R5
C906R
R6
C912B/R914R
R7
R912B/R911L
R8
R9056T,
L909L, L901T,
R910B
R9
R902B
* The R, L, T, and B values at the end of the part names indicate the Right, Left, Top,
and Bottom side of the part respectively in
Page 26
27
for an illustration of the test points.
Table 14: Rx RF Troubleshooting
Typical
Value/
Function
Frequency
HP85024A
RF-IN
-25 dBm/
881.52 MHz
LNA-In
-35dBm/
881.52MHz
LNA-Out
-13/-31dBm
881.52MHz
RF Filter Output
-18/-35dBm
Mixer-In
881.52MHz
Mixer-out
-5/-21dBm
183.6 MHz
IF Output to
+1.5/-15dBm
N700
183.6MHz
L.O Input to
-2.5dBm
N901
1065.12MHz
VR4
2.7V dc
Rx-SW1
H.G = 2.7V
L.G = 0V
©2005 Nokia Corporation
Nokia Customer Care
Typical
Value
Comments
Frequency
Prod Probe
-42 dBm
Input Connector reference
881.52 MHz
level
-42dBm
Test Duplexer insertion Loss
881.52MHz
(Without DC Block)
-29/-45dBm
Test LNA gain ~ 13dB
881.52MHz
-30/-45dBm
Test RF Filter Insertion loss
881.52MHz
(Without DC Block)
-23/-38dBm
Test Output on
183.6MHz
Downconverter on N901
-12/-29dBm
Test N2302 output to N700
183.6MHz
IF-IC
-18dBm
Test VCO output to N2302
1065.12MHz
Levels are for Channel 384
Power supply to N2302
LNA gain control, on the
N2302 side, High Gain >
2.5V dc
Figure
18.
Company Confidential