Menu 3, DGP settings
Menu 3 provides for some additional settings related directly to
the DGP functionality. Use the MENU key to change the
settings. Use ENTER to accept the settings and move to the
next item.
1. DGP configuration: selects the number of inputs and
outputs used. Available settings:
1 DGP Address: Allows for max 16 inputs/outputs to be
connected. Shows as "DGP: n" where n is the selected
DGP address in menu 1, DGP status (Default setting)
1 DGP+exp: Allows for max 32 inputs/16 outputs to be
connected. Shows as "DGP: n + exp" where n is the
selected DGP address in menu 1, DGP status.
2 DGP Addresses: Allows for max 32 inputs/outputs to be
connected but requires DGP polling to be enabled for the
DGP address and the DGP address + 1. Shows as "DGP:
n + m" where n is the selected DGP address and m is the
address + 1 in menu 1, DGP status.
2. Battery load: Select if the battery load resistor should be
enabled on output 8. It will follow the battery test and add an
additional 68 Ω during the test. This option is required for
regulations (SKAFOR). Default is OFF.
Note:
The setting must correspond with position of the battery
load resistor jumper (Figure 5, item 5).
3. Mains check: Enable/disable mains check. Set to OFF in
case no mains power supply is used to avoid mains fail being
reported. Default is ON.
4. Extended mode: To enable anti-mask detection it is
necessary to select Extended mode. Standard mode is needed
for backwards compatibility. Default is Extended mode.
5. Static outputs: Select whether to support static outputs
(max 8) or clocked outputs (max 32, depending on DGP
configuration). Default is Static outputs.
Menu 4, Factory reset
Use this menu to set all DGP configurations to default factory
settings.

Technical specifications

Mains power specifications
Mains Input Voltage (J17 – AC)
Current consumption at 230V~
Main board supply voltage
Power supply specifications
Power supply voltage
Power supply current
Auxiliary Power output* (J14)
Battery Power output (J17 – BAT)
Battery Type and max. capacity
Main board consumption
* Maximum permanent current to power devices external to the control
equipment in the absence of alarm conditions.
P/N 1064130 (ML) • REV E • ISS 01JUL19
230 VAC 10%, 50 Hz 10%
360 mA
23 VAC typical
13.8 VDC 5%
2.9 A max. at 13.8 VDC 5%
13.8 VDC 5%
For current see table below
13.8 VDC 5%.
For current see table below
Lead acid rechargeable 2 x
25 Ah 12 V nom. (BS129)
75 mA at 13.8 VDC 5%
Available Aux/Battery current based on backup
Time (h)
Incert
24
24
Aux
Battery
EN 1&2
12
72
Aux
Battery
EN 3&4
60
24
Aux
Battery
NF&A2P
36
30
Aux

Battery
NF&A2P
72
30
Aux

Battery
VdS
30
24
Aux
B
Battery
VdS
60
24
Aux
C
Battery
General feature specifications
End of line resistor
4.7 kΩ5% 0.25 W (2.2 kΩ or 10 kΩ)
(standard)
Ext. siren (J13 — S+/S−)
Standard on board output
Electronic output
Rating: 1 A at 13.8 VDC
Housing dimensions
ATS1203(N): 370 x 475 x 160 mm
ATS1204(N): 460 x 475 x 160 mm
Colour
Beige
−10 to +55°C (certified +5 to 40°C)
Operating temperature
Humidity
95% noncondensing
IP protection grade
IP30
Fuses
F4
Auxiliary
F2 A, 20x5
power & siren
F5
Battery
F3 A, 20x5
ATS1203: Slow T – 400 mA 20x5
[1]
Mains fuse
ATS1203NN/ATS1204(N): Fast F– 630 mA
20x5
[1]
Mains fuse is part of the mains terminal block.
WARNING:
Before removing the mains fuse, mains power
must be disconnected!

Regulatory information

Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Battery capacity (Ah)
7.2
18
25
36
Current (mA)
200
600
875
1200
2525
2125
1850
1525
490
1300
1800
1800
2235
1425
925
925
40
220
330
500
2685
2500
2395
2225
110
360
550
850
2615
2350
2200
1875
20
150
230
380
2700
2600
2500
2345
150
500
700
1050
2575
2225
2025
1675
40
220
330
500
2685
2500
2395
2225
50
1200
1525
1800
925
550
2175
1000
1725
580
2100
1100
1625
550
2175
7 / 24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ats1204(n)

Table of Contents